Veterinary and Comparative Orthopaedics and Traumatology· 2026Q2
Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats
- 0citations
- Q2SCImago
- 2026year
Short summary
A 1.7 mm locking bone plate system (Fixin) achieved 77% complete healing in 100 appendicular fractures in dogs and cats, with a 15% complication rate.
AI-generated from the title and abstract; the full text is not read.
Key points
- The Fixin 1.7 mm locking plate system was used to stabilize appendicular fractures in 100 dogs and cats.
- Complete radiographic healing occurred in 77% of the evaluated fractures.
- The overall complication rate was 15%, with 19% in minimally invasive procedures and 13% in open procedures.
- The system demonstrated comparable outcomes to existing micro-locking systems.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract To retrospectively evaluate the stabilization of appendicular fractures using the Fixin 1.7 mm locking plate system in dogs and cats. A review of patient medical records with traumatic appendicular fractures stabilized with the Fixin 1.7 mm locking plate was performed. Fractures were excluded due to lack of follow-up radiographs, prophylactic plating, or the use of additional plates. Data pertaining to the signalment, fracture classification, implants, evidence of radiographic healing, and limb function were recorded. Stabilization included both minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) methods. Outcomes were determined from clinical and radiographic follow-ups. One hundred out of 133 evaluated fractures met inclusion criteria. Median age and weight were 3 (IQR 1–6) years and 3.46 (IQR 2.5–4.78) kg. Complete healing occurred in 29/37 (78%) MIPO and 48/63 (76%) ORIF cases, for a combined outcome of 77/100 (77%). Complications occurred in 7/37 (19%) fractures repaired via MIPO and 8/63 (13%) fractures repaired via ORIF, with an overall complication rate of 15/100 (15%). Results suggest the Fixin 1.7 mm system provides acceptable outcomes comparable to existing micro-locking systems in appropriately selected cases.
The authors' abstract, as published at the source. Veterinary and Comparative Orthopaedics and Traumatology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Small AnimalsVeterinary