PofoliaDaily literature tracker

Scientific Reports· 2026Q1

Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora

Mohammad Imad Awad Ghannam, Nur Arfian, Arif Faisal, Yudha Mathan Sakti

Short summary

CT-based 3D morphometry of the proximal femur shows excellent inter-rater reliability (ICC 0.936–0.995) for six linear dimensions and distal canal diameter (FCD2), but moderate reliability for femoral anteversion (FAA; ICC 0.676) and proximal canal diameter (FCD1; ICC 0.705).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Six linear dimensions and distal canal diameter (FCD2) of the proximal femur show excellent inter-rater reliability (ICC 0.936–0.995).
  • Femoral anteversion (FAA) and proximal canal diameter (FCD1) exhibit moderate inter-rater reliability (ICC 0.676 and 0.705, respectively).
  • Significant systematic differences between raters were observed for FAA (4.55°), FCD1 (1.13 mm), and FCD2 (0.49 mm).
  • Femoral anteversion (FAA) has the largest measurement error, with SEM of 4.90° and limits of agreement from -9.0° to +18.2°.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Computed tomography (CT)-based three-dimensional (3D) morphometry is widely used to describe the proximal femur, yet the measurement properties of individual parameters are rarely reported. We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora. Reliability was quantified with the intraclass correlation coefficient [ICC(2,1)], measurement error with the standard error of measurement (SEM) and minimal detectable change, and agreement and systematic bias with Bland–Altman analysis and paired t-tests. Six linear dimensions and the distal canal diameter (FCD2) showed excellent reliability (ICC 0.936–0.995; SEM 0.32–1.31 mm). The neck-shaft angle showed good reliability (ICC 0.778), and femoral anteversion (FAA; ICC 0.676) and the proximal canal diameter (FCD1; ICC 0.705) moderate reliability. Significant systematic differences between raters occurred for FAA (4.55°), FCD1 (1.13 mm) and FCD2 (0.49 mm), the latter despite excellent reliability. FAA had the largest measurement error (SEM 4.90°; limits of agreement − 9.0° to + 18.2°). These results describe agreement between two raters under one protocol; they do not establish anatomical accuracy, which requires comparison with a reference standard.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Statistics, Probability and UncertaintyDecision Sciences