PofoliaDaily literature tracker

Nanotechnology· 2026Q2

Measurements, simulations, and models of the point-spread function of electron-beam lithography

Nikolaj Balslev Hougs, Kristian Sofus Knudsen, Marcus Albrechtsen, Taichi Suhara et al.

Short summary

A new model, combining a power-law and a Gaussian, accurately describes electron scattering in lithography, outperforming the traditional double-Gaussian model by up to four orders of magnitude.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The double-Gaussian model for electron scattering in lithography is highly inaccurate for modern systems, deviating by up to four orders of magnitude.
  • A novel model, comprising a power-law and a Gaussian, accurately represents the point-spread function of electron scattering.
  • The proposed model shows excellent agreement with Monte Carlo simulations and experimental data across a range of voltages (5 kV to 150 kV) and substrates.
  • The power-law term in the new model is remarkably constant, while long-range dose contributions and clearing dose vary with substrate and voltage.

AI-generated from the title and abstract; the full text is not read.

Abstract

When a sample is exposed using electron-beam lithography, the electrons scatter deep and far in the substrate, resulting in unwanted deposition of dose at both the nano- and the microscale. This proximity effect can be mitigated by proximity effect correction provided that accurate and validated models of the point-spread function of the electron scattering are available. Most works so far considered a double-Gaussian model of the electron point-spread function, which is very inaccurate for modern electron-beam writers with high acceleration voltages. We present measurements of the process point-spread function for chemically semi-amplified resist on silicon and indium phosphide substrates using a 150 kV electron-beam lithography system. We find that the double-Gaussian model deviates from experiments by up to four orders of magnitude. We propose instead a model comprising the sum of a power-law and a Gaussian, which is in excellent agreement with simulations of the electron scattering obtained by a Monte Carlo method. We apply the power-law plus Gaussian model to quantify the electron scattering and proximity effect correction parameters across material stacks, processing, and voltages from 5 kV to 150 kV. We find that the power-law term remains remarkably constant, whereas the long-range dose contributions and the clearing dose are significantly affected by the substrate and the acceleration voltage. Combined, the results imply that reliance on the double-Gaussian approximation in proximity-effect correction has become a limiting factor for resolution in fabrication at the nanoscale.

The authors' abstract, as published at the source. Nanotechnology, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Electrical and Electronic Engineering

Electrical and Electronic EngineeringEngineering