PofoliaDaily literature tracker

Scientific Reports· 2026Q1

Deep learning classifies calcium imaging dynamics using time-series representations

Caroline L. Alves, Simone Hufgard, Andriana S. L. O. Campanharo, Loriz Francisco Sallum et al.

Short summary

A deep learning framework accurately classifies neuronal calcium imaging dynamics, achieving 0.99 precision, 0.99 sensitivity, and 0.99 specificity, independent of segmentation methods.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed a deep learning framework for classifying calcium imaging dynamics that is segmentation-agnostic.
  • Transformed time-series data into fixed-size matrices using quantile transition patterns.
  • Achieved high classification performance with precision, sensitivity, and specificity of 0.99 in independent validation.
  • Demonstrated robustness to reduced temporal resolution and moderate noise perturbations.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Calcium imaging data are challenging to analyze reliably because signal extraction and segmentation can vary across recordings and acquisition settings. This study aims to develop a segmentation-agnostic deep learning framework for classifying neuronal dynamics across different spatial resolutions and acquisition frequencies. Fluorescence time series were transformed into compact, fixed-size matrices based on quantile transition patterns. These standardized representations were classified using convolutional neural networks. Performance was evaluated using stratified hold-out testing and receiver operating characteristic analysis. Multiple quantile-based representations were evaluated under whole-image and grid-based preprocessing strategies, and robustness was assessed under reduced temporal resolution and controlled noise perturbations. Across all preprocessing strategies and representation variants, the framework achieved strong and consistent classification performance, achieving precision = 0.99, sensitivity = 0.99, and specificity = 0.99 in independent validation. Classification performance remained high under moderate noise perturbations but declined progressively as perturbation magnitude increased. The proposed segmentation-agnostic framework provides a robust, scalable, and generalizable strategy for analyzing calcium imaging dynamics, enabling efficient characterization of neuronal activity in pharmacological and systems neuroscience applications.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

BiophysicsBiochemistry, Genetics and Molecular Biology