Yüksek bir binanın merdiveninde tek bir çıkan yaya, 12 katı (3. Kat-14. Kat) etkileyen ve daha yüksek katlarda 38 saniyeye kadar süren bir tıkanıklık durma dalgasına neden oldu; tıkanıklık yoğunluğu 1.36 p/m²'den 2.18 p/m²'ye yükseldi.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Yüksek bir binanın merdiveninde tek bir çıkan yaya, 14 katı etkileyen bir tıkanıklık durma dalgası başlattı.
  • Durma dalgası en az 3 saniye boyunca 12 katı (3. Kat-14. Kat) etkiledi.
  • Tıkanıklık süresi kat yüksekliğiyle arttı, 3. Katta 10 saniyeden 13. Katta 38 saniyeye kadar çıktı.
  • Tepe yaya yoğunluğu, etkilenen katlarda normal akış ortalaması olan 1.36 p/m²'den tıkanık ortalama olan 2.18 p/m²'ye yükseldi.
  • Tıkanıklık cephesi, 3-14. Katlar arasında 0.861 m/s hızla yayıldı.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

In high-rise fire emergencies, ascending firefighters must enter the staircase while occupants are still descending—a structurally unavoidable form of bidirectional flow. Counterflow is recognized as a contributor to staircase congestion, but its building-wide propagation has not been quantified from field data. This observational field study analyzes video counts from a full-building evacuation drill at a 22-story office building (≈2,400 participants); the drill was conducted as a phased evacuation, which serves as the observational context. The analysis focuses on a counterflow event during the normal flow period—after phase-related merging had concluded—isolating counterflow effects from merging. A single pedestrian ascending from Floor 1 to Floor 2 was followed by flow disruption across 14 floors (M2–14F); the stop wave satisfying the ≥ 3-s criterion spanned 12 floors (3F–14F). Congestion duration increased with floor height, from 10 s at Floor 3 to a maximum of 38 s at Floor 13, whereas peak density showed no floor-level trend but was uniformly elevated across affected floors, from a normal-flow mean of 1.36 p/m 2 to a congested mean of 2.18 p/m 2 . The apparent congestion front speed over Floors 3–14 was 0.861 m/s, with onset time increasing almost linearly with path distance, indicating a single coherent front; the resolution front advanced at 0.734 m/s, about 15 % more slowly. These findings provide field-based evidence of the floor-by-floor amplification of congestion duration and motivate—as a safety hypothesis requiring further validation—counterflow-aware evacuation planning where firefighter ascent may coincide with occupant descent.

Yazarların özeti; kaynağından alınmıştır. Safety Science, 2026 · DOI ↗

ÇıkarımlarPremium Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 5 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Güvenlik Araştırmaları

Safety ResearchSocial Sciences