Physical Review Applied· 2026Q1
Mitigating effects of nonlinearities in homodyne quadrature interferometers
- 3citations
- Q1SCImago
- 2026year
Short summary
A new method significantly suppresses nonlinearities in homodyne quadrature interferometers (HoQIs), enabling sub-pm sensitivity over a micrometer range and broadening their applicability in precision sensing, including gravitational wave detectors.
AI-generated from the title and abstract; the full text is not read.
Key points
- Nonlinearities in HoQIs limit their precision displacement sensing capabilities.
- A novel method quantifies and suppresses these nonlinearities using a mechanical resonator.
- Real-time suppression via ellipse fitting achieves sub-pm sensitivity above 1 Hz for micrometer-scale motions.
- Post-processing can further improve accuracy by an order of magnitude.
- The findings enhance HoQI applicability, particularly for gravitational wave detectors.
AI-generated from the title and abstract; the full text is not read.
Abstract
Homodyne Quadrature interferometers (HoQI) use an interferometric displacement sensing scheme with excellent noise performance, making them a strong candidate for precise sensing and control of positions of objects. All interferometers are prone to nonlinear effects when measuring dynamic displacements. These nonlinearities, if left unsuppressed, would introduce significant displacement measurement errors and therefore substantially limit the use cases of HoQIs. This paper experimentally demonstrates a means of quantifying and addressing nonlinearities for a broad range of use cases using a HoQI as a test bed and a narrow line width mechanical resonator to induce very linear displacement signals. As nonlinearities scale differently with the magnitude of the input signal, this work studies mitigation and suppression techniques for input motion ranging from a few nm to about 500,nm. Furthermore, both real-time and post processing possibilities of nonlinearity mitigation are investigated. Our work shows that initial nonlinearities in HoQIs can be significantly suppressed in real time by conventional ellipse fitting and that the parameters are sufficiently stable over a month. With this, the HoQI reaches sub-pm sensitivity above 1,Hz, while detecting a motion range of the order of a micrometre. If the data is not needed in real time, it can be corrected by up to another order of magnitude using alternative techniques. Overall, our work makes HoQIs a more broadly applicable tool for displacement sensing in a range of different use cases, in particular, their intended implementation in gravitational wave detectors.
The authors' abstract, as published at the source. Physical Review Applied, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Mechanical Engineering
Mechanical EngineeringEngineering