PofoliaDaily literature tracker

Environmental Research Letters· 2026Q1

Spatially distributed air quality and health impacts of data center electricity demand in the United States

Yuang Chen, Shen Wang, Juan Senga, Andrew White et al.

Short summary

Data center electricity demand in the US in 2023 caused an estimated 513 premature mortalities from PM2.5 and 137 from ozone, with significant geographic mismatches between where demand occurs and where health impacts are felt.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Data center electricity demand in 2023 resulted in an estimated 513 annual premature mortalities from PM2.5 and 137 from ozone in the contiguous US.
  • This demand increased annual mean PM2.5 concentrations by 0.02–0.08 μg m⁻³, with local peaks up to ~0.2 μg m⁻³.
  • The health impacts are spatially mismatched, with some states experiencing burdens disproportionate to their data center electricity consumption.
  • This mismatch is attributed to interconnected electricity grids, regional generation and emissions, and atmospheric chemistry/transport.

AI-generated from the title and abstract; the full text is not read.

Abstract

The rapid expansion of artificial intelligence is driving substantial growth in electricity demand from data centers in the US, yet how the resulting air quality and public health impacts are distributed remain poorly quantified. To trace the ambient air pollution and associated premature mortality impacts of grid-supplied data center electricity demand in 2023, we couple the United States Electricity Generation Optimization model with the GEOS-Chem chemical transport model. We compare hourly, unit-level electricity dispatch with and without data center demand to quantify changes in power-sector emissions, ambient PM 2.5 and ozone, and associated premature mortality. Our results show that electricity generation attributable to data center demand is largely supplied by fossil fuel units across multiple regions, resulting in additional annual mean PM 2.5 concentrations of 0.02–0.08 μ g m − 3 (local peak concentrations up to ∼ 0.2 μ g m − 3 ), and regionally varying ozone responses characterized by wintertime depletion and summertime enhancement. These impacts are most pronounced in the Midwest United States, where marginal emissions from coal-fired units and ammonia-rich atmospheric conditions enhance secondary particulate formation. We estimate that this grid-supplied demand is responsible for 513 (95% CI: 469–557) annual premature mortalities from PM 2.5 and an additional 137 (95% CI: 90–183) annually from maximum daily 8 h average ozone (MDA8- O 3 ) in the contiguous US. State-level analysis reveals a systematic geographic mismatch: states hosting the largest data center loads do not necessarily experience the highest attributable mortality rates, while some states with little data center demand bear substantial burdens. This mismatch arises because of dispatch across interconnected electricity regions, regional differences in generation and emissions, and atmospheric chemistry and transport, which together separate the locations of demand from those of exposure and mortality. These findings highlight the importance of considering both air quality impacts and their spatial distribution in data center and macro-energy system planning.

The authors' abstract, as published at the source. Environmental Research Letters, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Health, Toxicology and MutagenesisEnvironmental Science