Clinical Chemistry and Laboratory Medicine (CCLM)· 2026Q1
Extending external quality assessment to cover what is missing from the quality indicators we currently measure?
- 0citations
- Q1SCImago
- 2026year
Short summary
New external quality assessment (EQA) schemes are proposed to address unmeasured post-analytic errors, such as inappropriate reference intervals and non-standardized result flagging, which impact patient safety and laboratory reputation.
AI-generated from the title and abstract; the full text is not read.
Key points
- Current quality indicators primarily focus on pre- and analytic errors, neglecting significant post-analytic issues.
- Post-analytic errors like inappropriate reference intervals and non-standardized flagging are difficult to detect and manage.
- Existing EQA systems do not adequately provide peer comparison for these critical post-analytic functions.
- New EQA schemes are needed to assess patient reports, focusing on format and information content differences.
AI-generated from the title and abstract; the full text is not read.
Abstract
Clinical laboratories routinely use quality indicators to monitor pre- and analytic error. Post-analytic error is more difficult to define. It is usually defined as unacceptable turnaround times for results or corrected results, failure to notify a clinician of a critical result or a corrected report, or failure to hand over results or amended results. However, some post-analytic errors affecting patient safety and laboratory reputation are not managed well. These are the use of inappropriate reference intervals, the non-standardisation of abnormal-result flagging, and the non-harmonisation of methods. These errors are in plain sight, and yet laboratory staff fail to rank them as significant as other errors. The first two types of post-analytic error are not apparent to the laboratory unless a clinician files a complaint. This is partly because there are no EQA systems to provide peer comparison of these functions. The results of assay non-harmonisation are apparent on EQA reports, but laboratory staff are usually content if their results are within the APS for their method group. What is required is analytical standardisation and harmonisation; harmonisation of reference intervals and decision limits; standardised presentation and flagging; and quality assurance of the final report received by clinicians and patients. Solving this problem requires creating new forms of EQA focused on patient reports, whether electronic or paper, that highlight differences in report formats and information content.
The authors' abstract, as published at the source. Clinical Chemistry and Laboratory Medicine (CCLM), 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Medical Laboratory TechnologyHealth Professions