Enabling gesture recognition on a resource-constrained device: a TinyML approach with envelope EMG data and real-time testing
- 2citations
- Q2SCImago
- 2026year
Short summary
A TinyML pipeline achieved 98.35% accuracy in classifying hand and arm gestures from envelope EMG data on a low-cost microcontroller, using only 9.1% of flash memory and 10.6% of SRAM with a 23ms inference time.
AI-generated from the title and abstract; the full text is not read.
Key points
- A TinyML pipeline successfully classifies hand and arm gestures from envelope EMG data on a resource-constrained microcontroller.
- The artificial neural network (ANN) model achieved 98.35% test accuracy, with 97.22% in subject-independent evaluations.
- The deployed model uses 9.1% of flash memory and 10.6% of SRAM on a Raspberry Pi Pico, with a 23ms inference time.
- Real-time testing showed per-gesture accuracy ranging from 95.8% to 99.6% over 500 predictions.
AI-generated from the title and abstract; the full text is not read.
Abstract
Gesture recognition from electromyography (EMG) is used to control prostheses and rehabilitation devices, but real-time classifiers must balance accuracy, latency, cost and computational load. This paper presents a tiny machine learning (TinyML) pipeline that classifies hand and arm gestures from envelope EMG on a low-cost microcontroller. Four-channel envelope EMG was recorded with a six-lead myoelectric module and an Arduino UNO from 10 healthy participants, who performed six gestures for 4 s each in two sessions. A joint accuracy-complexity search selected the window length, overlap and four time-domain features used to train an artificial neural network (ANN). On a 60/20/20 window-level training/validation/test split, the test accuracy was 98.35%. Five-fold cross-validation (97.37 ± 1.05%) indicated stable performance across data partitions, and leave-one-subject-out (LOSO) evaluation, the only subject-independent test, gave 97.22 ± 1.33%. Compared with a support vector machine (SVM), k-nearest neighbours (KNN), a decision tree and a random forest, the ANN had the lowest golden distance (GD = 0.0325). Deployed on a Raspberry Pi Pico in TensorFlow Lite format, the model uses 9.1% of flash memory and an estimated 10.6% of static random-access memory (SRAM), with a 23 ms inference time, a 254 ms total on-device cycle and a 12.9% active processing duty cycle. In a representative real-time test, with a PC relaying the EMG data to the Pico, per-gesture accuracy over 500 consecutive predictions was 95.8–99.6%. These results show that real-time envelope-EMG gesture recognition is feasible on a resource-constrained microcontroller; with validation on larger and more diverse populations, the approach may inform human-machine interfaces for prosthetics, rehabilitation and assistive devices.
The authors' abstract, as published at the source. Journal of Edge Computing, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Biomedical Engineering
Biomedical EngineeringEngineering