Commercial Screen-Printed Electrodes as pH Voltammetric Sensors

Alex Campos, Luna Ipharraguerre, Clara Pérez‐Ràfols, Núria Serrano et al.

Short summary

Commercial gold screen-printed electrodes (SPAuEs), after HCl pretreatment and regeneration, demonstrate reliable voltammetric pH sensing across a wide range (pH 2–12) with inter-electrode reproducibility and temporal stability within ±0.12 pH units.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Commercial gold screen-printed electrodes (SPAuEs) can function as voltammetric pH sensors.
  • HCl pretreatment and an intermediate acidic regeneration step are crucial for reliable performance.
  • SPAuEs showed good inter-electrode reproducibility and temporal stability (±0.12 pH units).
  • Sensor performance is significantly affected by low ionic strength and the presence of chloride ions.

AI-generated from the title and abstract; the full text is not read.

Abstract

The development of miniaturized pH sensors suitable for routine analytical implementation remains a central challenge in electrochemical analysis. Here, a critical assessment of commercial screen-printed electrodes (SPEs) as voltammetric pH sensors is presented, focusing on their electrochemical response, analytical response and practical limitations. Screen-printed carbon electrodes (SPCEs) and screen-printed gold electrodes (SPAuEs) were evaluated under minimal treatment. SPCEs exhibited no intrinsic pH sensitivity, and quinone-based electrochemically deposited layers showed insufficient stability for reliable measurements. In contrast, SPAuEs showed a well-defined pH-dependent response based on the reduction of electrochemically generated gold oxides. After HCl pretreatment, near- to super-Nernstian behaviour (up to 64 mV) was achieved over a wide pH range (2–12). SPAuEs demonstrated excellent inter-electrode reproducibility and good temporal stability, with variations not exceeding ±0.12 pH units. However, repeatability was affected by progressive surface modification, particularly at alkaline pH. This limitation was mitigated by introducing an intermediate regeneration step in acidic medium, which restores a consistent surface state. Accurate pH determinations were achieved across several buffer systems at 0.1 mol L−1 ionic strength, whereas lower ionic strengths and chloride ions significantly affected sensor performance. These results demonstrate that a pH-dependent gold oxide response alone does not guarantee reliable pH measurements. Instead, successful implementation of commercial SPAuEs requires appropriate surface conditioning, regeneration procedures and control of matrix effects. By defining these operational requirements and limitations, this work establishes a practical framework for the reliable use of commercial SPAuEs as voltammetric pH sensors.

The authors' abstract, as published at the source. Chemosensors, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Electrochemistry

ElectrochemistryChemistry