Journal of Glaucoma· 2026Q1
Early Outcomes of the Paul Glaucoma Implant in Children With Refractory Glaucoma
- 1citations
- Q1SCImago
- 2026year
Short summary
The Paul glaucoma implant significantly reduced intraocular pressure (IOP) by approximately 64% and allowed for medication-free control in 93.3% of pediatric eyes within 6 months, with no sight-threatening complications.
AI-generated from the title and abstract; the full text is not read.
Key points
- Paul glaucoma implant surgery reduced median intraocular pressure by ~64% at 6 months in pediatric refractory glaucoma.
- 93.3% of eyes achieved medication-free intraocular pressure control at 6 months post-surgery.
- The procedure had a low complication rate, with one revision and no sight-threatening issues in 15 eyes.
- Median baseline IOP was 33.0 mmHg, with all eyes requiring 3 topical glaucoma medications.
AI-generated from the title and abstract; the full text is not read.
Abstract
Precis: İn a consecutive pediatric refractory glaucoma case series, Paul glaucoma implant surgery was associated with marked early intraocular pressure reduction and medication-free control at 6 months, with one revision and no sight-threatening complications. Purpose: To evaluate early intraocular pressure control, medication use, and short-term safety after Paul glaucoma implant surgery in children with refractory glaucoma. Materials and Methods: This retrospective consecutive interventional case series included 15 eyes of 15 pediatric patients who underwent Paul glaucoma implant surgery at a tertiary ophthalmic center in Azerbaijan between January 2023 and December 2025. The primary outcome was change in intraocular pressure from baseline through 6 months. Secondary outcomes included glaucoma medication use, complete success, additional surgical intervention, and postoperative complications. Paired intraocular pressure comparisons were performed using the Wilcoxon signed-rank test. Results: Median age at surgery was 4.8 years (interquartile range [IQR], 2.3 to 10.2 y), and 9 patients (60.0%) were male. Median baseline intraocular pressure was 33.0 mmHg (IQR, 30.0 to 35.0 mmHg), and all eyes were receiving 3 topical glaucoma medications. Median intraocular pressure decreased to 13.0 mmHg at week 1 ( P <0.001), 22.0 mmHg at month 1 ( P =0.004), 15.0 mmHg at month 3 ( P =0.004), and 12.0 mmHg at month 6 ( P <0.001), corresponding to an approximate 64% mean reduction from baseline at 6 months. At 6 months, 14 eyes (93.3%) achieved complete success without glaucoma medications. One eye (6.7%) required tube revision. No implant-related sight-threatening complications were documented. Conclusions: In this early real-world pediatric series, the Paul glaucoma implant was associated with substantial intraocular pressure reduction and a high rate of medication-free control at 6 months. Longer prospective comparative studies are required to confirm durability of pressure control and late safety outcomes.
The authors' abstract, as published at the source. Journal of Glaucoma, 2026 · DOI ↗