3D-DXA cortical and trabecular parameters: agreement and precision between GE Healthcare Prodigy and iDXA densitometers
- 6citations
- Q2SCImago
- 2026year
Short summary
GE Healthcare's Prodigy and iDXA densitometers show high agreement (95.5% for cortical sBMD, 95.2% for trabecular vBMD) in classifying bone density using 3D-DXA, with comparable short-term precision errors.
AI-generated from the title and abstract; the full text is not read.
Key points
- 3D-DXA measurements of cortical and trabecular bone show high diagnostic classification agreement between GE Prodigy and iDXA densitometers.
- Agreement reached 95.5% for cortical sBMD and 95.2% for trabecular vBMD in a cohort spanning all bone density categories.
- Short-term precision errors for 3D-DXA parameters were comparable across both scanner models.
- The findings support the use of 3D-DXA across these GE Healthcare models for cross-sectional diagnostic purposes.
AI-generated from the title and abstract; the full text is not read.
Abstract
Summary We assessed agreement and precision of 3D-DXA parameters between Prodigy and iDXA densitometers in adults. Strong agreement was observed between devices, and short-term precision was comparable. Moreover, high inter-scanner diagnostic classification agreement was found in the cohort spanning the full range of bone density categories, supporting the use of 3D-DXA across these GE Healthcare models for cross-sectional diagnostic purposes. Purpose 3D-DXA reconstructs DXA hip scans to 3-dimensional images, allowing measurement of trabecular and cortical bone parameters. Differences in imaging characteristics between the GE Healthcare iDXA and Prodigy could influence 3D-DXA results. This study evaluated the agreement and precision of 3D-DXA cortical and trabecular femur parameters between Prodigy and iDXA densitometers. Methods A total of 391 adults from 3 clinical centers in the United States and Brazil underwent hip scans on both Prodigy and iDXA scanners, subsequently analyzed with 3D-Shaper software. Short-term precision was assessed on three Prodigy and two iDXA densitometers. Agreement was assessed by regression, Bland-Altman analyses, and diagnostic classification agreement analysis. Short-term precision was determined following International Society for Clinical Densitometry recommendations. Results Bland-Altman analyses demonstrated statistically significant differences in aBMD and 3D-DXA measurements between Prodigy and iDXA scanners; however, diagnostic classification agreement was high. In the largest cohort, the only one spanning all three classification categories, agreement was 95.5% for cortical sBMD and 95.2% for trabecular vBMD (κw = 0.90 for both), comparable to total hip aBMD (97.3%, κw = 0.94). Short-term precision errors (RMS-SD) were 0.006 to 0.011 g/cm² for total hip aBMD, 0.009 to 0.023 g/cm² for femoral neck aBMD, 2.989 to 4.139 mg/cm³ for integral vBMD, 2.116 to 2.392 mg/cm² for cortical sBMD and 3.073 to 3.909 mg/cm³ for trabecular vBMD. Conclusion Under the conditions evaluated, aBMD and 3D-DXA bone measurements demonstrate comparable short-term precision and inter-scanner diagnostic classification agreement across Prodigy and iDXA densitometers.
The authors' abstract, as published at the source. Archives of Osteoporosis, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Orthopedics and Sports Medicine
Orthopedics and Sports MedicineMedicine