3D-DXA cortical and trabecular parameters: agreement and precision between GE Healthcare Prodigy and iDXA densitometers

Diane C. Krueger, Neil Binkley, Miguel Madeira, Zhaojing Chen et al.

Short summary

GE Healthcare's Prodigy and iDXA densitometers show high agreement (95.5% for cortical sBMD, 95.2% for trabecular vBMD) in classifying bone density using 3D-DXA, with comparable short-term precision errors.

AI-generated from the title and abstract; the full text is not read.

Key points

  • 3D-DXA measurements of cortical and trabecular bone show high diagnostic classification agreement between GE Prodigy and iDXA densitometers.
  • Agreement reached 95.5% for cortical sBMD and 95.2% for trabecular vBMD in a cohort spanning all bone density categories.
  • Short-term precision errors for 3D-DXA parameters were comparable across both scanner models.
  • The findings support the use of 3D-DXA across these GE Healthcare models for cross-sectional diagnostic purposes.

AI-generated from the title and abstract; the full text is not read.

Abstract

Summary We assessed agreement and precision of 3D-DXA parameters between Prodigy and iDXA densitometers in adults. Strong agreement was observed between devices, and short-term precision was comparable. Moreover, high inter-scanner diagnostic classification agreement was found in the cohort spanning the full range of bone density categories, supporting the use of 3D-DXA across these GE Healthcare models for cross-sectional diagnostic purposes. Purpose 3D-DXA reconstructs DXA hip scans to 3-dimensional images, allowing measurement of trabecular and cortical bone parameters. Differences in imaging characteristics between the GE Healthcare iDXA and Prodigy could influence 3D-DXA results. This study evaluated the agreement and precision of 3D-DXA cortical and trabecular femur parameters between Prodigy and iDXA densitometers. Methods A total of 391 adults from 3 clinical centers in the United States and Brazil underwent hip scans on both Prodigy and iDXA scanners, subsequently analyzed with 3D-Shaper software. Short-term precision was assessed on three Prodigy and two iDXA densitometers. Agreement was assessed by regression, Bland-Altman analyses, and diagnostic classification agreement analysis. Short-term precision was determined following International Society for Clinical Densitometry recommendations. Results Bland-Altman analyses demonstrated statistically significant differences in aBMD and 3D-DXA measurements between Prodigy and iDXA scanners; however, diagnostic classification agreement was high. In the largest cohort, the only one spanning all three classification categories, agreement was 95.5% for cortical sBMD and 95.2% for trabecular vBMD (κw = 0.90 for both), comparable to total hip aBMD (97.3%, κw = 0.94). Short-term precision errors (RMS-SD) were 0.006 to 0.011 g/cm² for total hip aBMD, 0.009 to 0.023 g/cm² for femoral neck aBMD, 2.989 to 4.139 mg/cm³ for integral vBMD, 2.116 to 2.392 mg/cm² for cortical sBMD and 3.073 to 3.909 mg/cm³ for trabecular vBMD. Conclusion Under the conditions evaluated, aBMD and 3D-DXA bone measurements demonstrate comparable short-term precision and inter-scanner diagnostic classification agreement across Prodigy and iDXA densitometers.

The authors' abstract, as published at the source. Archives of Osteoporosis, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthopedics and Sports Medicine

Orthopedics and Sports MedicineMedicine