Characterization of the GIGAPYX-4600 CMOS visible image sensor in the context of high precision astrometry

Manon Lizzana, Sébastien Soler, Fabrice Pancher, Éric Thiébaut et al.

Short summary

The GIGAPYX-4600 CMOS image sensor demonstrates high linearity (0.90±0.18% error), low pixel response non-uniformity (≤1.3%), and minimal readout noise (12±3 e−), making it a strong candidate for next-generation space astrometry missions.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The GIGAPYX-4600 sensor has linearity errors of 0.90±0.18% and pixel response non-uniformity ≤1.3%.
  • Readout and quantization noise is measured at 12±3 e− in low-gain mode.
  • Dark current is 35±1 e−/s at 35°C, with defective pixels accounting for only 8×10−5% of the array.
  • The sensor showed robustness against protons and heavy ions, with no latch-up observed during radiation tests.

AI-generated from the title and abstract; the full text is not read.

Abstract

To evaluate the potential of detectors for next-generation space astrometry missions such as the Habitable Worlds Observatory and Theia, an extensive analysis of the performance of the GIGAPYX-4600 46-megapixel CMOS detector from Pyxalis was conducted at Institut de planétologie et d’astrophysique de Grenoble. The 5456×8320-pixel detector, featuring a 4.4-μm pitch and back-side illumination, constitutes a matrix of 24×36 mm. It has a measured gain of 13.3±0.9 e−/ADU in low-gain mode. The saturation level of the detector in low-gain-mode is estimated to be ∼56 ke−. This sensor demonstrates linearity errors of 0.90±0.18%, pixel response nonuniformity ≤1.3%, and readout and quantization noise of 12±3 e− in low-gain mode. Dark current was measured at 35±1 e−/s at 35°C, defective pixels accounted for only 8×10−5% of the array, and inter-pixel capacitance remained under 3%. We demonstrated that inter-pixel capacitance effects can be effectively mitigated using spatially varying kernel correction algorithms. Radiation tests confirmed its robustness against protons and heavy ions, and no latch-up was observed. These measurements agree with the manufacturer figures. These characterization results validate the GIGAPYX-4600 as a strong candidate for high-precision astrometry. Further improvements are currently being developed for space implementation.

The authors' abstract, as published at the source. Journal of Astronomical Telescopes Instruments and Systems, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Electrical and Electronic Engineering

Electrical and Electronic EngineeringEngineering