Energy and Buildings· 2026Q1
A hybrid data-driven and physics-informed framework for residential heating flexibility assessment
- 1citations
- Q1SCImago
- 2026year
Short summary
A new hybrid framework combining data-driven forecasting and physics-informed modeling quantifies residential heating flexibility, identifying 27.34 kWh of admissible reduction across a case study portfolio.
AI-generated from the title and abstract; the full text is not read.
Key points
- A hybrid framework combines data-driven forecasting (Mamba model achieved R2 > 0.8) and physics-informed simulation to assess residential heating flexibility.
- Flexibility is quantified using a Heating Flexibility Indicator (HFI) and energy (kWh) while respecting comfort and indoor air quality constraints.
- The framework identified 27.34 kWh of admissible heating reduction across 17 apartments in two Danish housing blocks.
- Seasonal analysis revealed spring offers the highest average HFI, while autumn provides the largest energy flexibility.
- Results indicate significant variation in flexibility across apartments and seasons, supporting selective demand response activation.
AI-generated from the title and abstract; the full text is not read.
Abstract
Residential heating can provide demand-side flexibility by temporarily reducing heat demand while maintaining acceptable indoor conditions. However, apartment-level flexibility is difficult to quantify because it depends on heating demand, thermal response, weather conditions, thermostat settings, and comfort constraints. This paper presents a hybrid data-driven and physics-informed framework for assessing downward heating flexibility in district-heated residential buildings. The framework combines short-term heating demand forecasting, apartment-specific thermal response modelling, and comfort-constrained simulation. Candidate heating reductions are evaluated using indoor temperature, PMV–PPD, relative humidity, and CO 2 constraints, and the maximum admissible reduction is expressed through a Heating Flexibility Indicator (HFI) and the corresponding energy flexibility in kWh. The framework is evaluated using hourly data from 17 apartments in two Danish residential social housing blocks. Ridge regression, Piecewise Ridge regression, and a physics-informed Mamba model are compared for baseline forecasting, with the Mamba model achieving the strongest overall performance and R 2 values above 0.8 for most apartments. For the case-study day, the framework identifies 27.34 kWh of admissible heating reduction across the portfolio, with 18.12 kWh from Block 1 and 9.22 kWh from Block 4. The seasonal analysis shows that spring provides the highest average HFI, whereas autumn provides the largest energy flexibility. The results indicate that residential heating flexibility varies across apartments, blocks, and seasonal operating conditions, supporting selective rather than uniform DR activation.
The authors' abstract, as published at the source. Energy and Buildings, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Building and Construction
Building and ConstructionEngineering