Microbial Genomics· 2026Q1
Detection of eukaryotic micro-organisms in human clinical samples by shotgun metagenomics: read-based thresholds and determinants of performance
- 2citations
- Q1SCImago
- 2026year
Short summary
A global threshold of 0.06 reads per million (RPM) for eukaryotic microorganisms in human clinical samples detected 87.8% of true positives with 90.7% specificity, establishing a quantitative framework for shotgun metagenomics.
AI-generated from the title and abstract; the full text is not read.
Key points
- Developed RPM-based detection thresholds for eukaryotic microorganisms in human clinical shotgun metagenomics.
- Microbial load, indicated by Cq values, was the primary determinant of SMg sensitivity.
- A global threshold of 0.06 RPM achieved high accuracy (AUC 0.93) across sample types.
- Blood and biological fluids showed the highest concordance between SMg and standard of care (F1 scores of 0.98 and 0.97).
AI-generated from the title and abstract; the full text is not read.
Abstract
Bioinformatic detection thresholds for eukaryotic micro-organisms (fungi and parasites) remain largely undefined in human clinical shotgun metagenomics (SMg), limiting standardized implementation. We retrospectively compared SMg with standard of care (SoC) across 198 clinical samples from 187 patients to derive reads per million (RPM)-based detection thresholds for fungi and parasites across 5 major sample types. Total nucleic acids were sequenced (≥10 million reads per library) and processed with the MetaMIC ® v2.2.1 pipeline. Read counts were normalized as RPM. SoC identified micro-organisms in 152/198 samples (76.8%), spanning 44 eukaryote genera and 57 species; all 46 SoC-negative samples were also negative by SMg. The overall genus-level F1-score was 0.84, with performance varying by sample type: blood and biological fluids achieved the highest concordance (F1=0.98 and 0.97, respectively). Microbial load was the principal determinant of SMg sensitivity, with quantification cycle (Cq) values (n =57) inversely correlating with RPM (Spearman’s ρ =−0.66, P <0.001) and no false negatives at Cq<28.6. Receiver operating characteristic-derived optimal thresholds ranged from 0.06 RPM (faeces, Area Under the Curve [AUC] 0.91) to 0.57 RPM (tissue biopsies, AUC 0.90). A global threshold of 0.06 RPM yielded an AUC of 0.93 (95% confidence interval: 0.90–0.95; sensitivity 87.8%, specificity 90.7%). These results establish a quantitative, RPM-based framework for eukaryotic micro-organism detection in clinical metagenomics and a foundation for future multi-platform benchmarking studies.
The authors' abstract, as published at the source. Microbial Genomics, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Microbiology
Microbiology (medical)Medicine