PofoliaDaily literature tracker

Sensors· 2026Q1

Validation of View-Specific Markerless Motion Analysis for Lower-Extremity Kinematics After Anterior Cruciate Ligament Reconstruction

Ayaka Tanaka, Issei Ogasawara, Akira Tsujii, Shuma Kinoshita et al.

Short summary

A markerless motion capture system (SPLYZA Motion) shows potential for assessing sagittal-plane lower-extremity range of motion (ROM) after ACL reconstruction during single-leg squats and hip flexion/extension during drop-jump landings, with accuracy varying by camera view and joint rotation.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Markerless motion capture (SPLYZA Motion) was compared to optical motion capture (OptiTrack) for lower-extremity kinematics post-ACL reconstruction.
  • Accuracy varied significantly by joint rotation and camera view: sagittal-plane angles were more accurate than frontal-plane angles.
  • Hip and knee flexion/extension ROM showed good reliability (ICC 0.78-0.93).
  • Ankle ROM and hip adduction/abduction/knee varus/valgus showed lower reliability (ICC 0.47-0.79 and 0.03-0.30, respectively).
  • Markerless analysis shows potential for sagittal-plane ROM during single-leg squats and hip flexion/extension during drop-jump landings.

AI-generated from the title and abstract; the full text is not read.

Abstract

Accurate evaluation of lower-extremity kinematics after anterior cruciate ligament (ACL) reconstruction is important for return-to-sport assessment. Markerless motion capture offers a portable alternative to optical motion capture, but its accuracy across joint rotations and tasks remains uncertain. We compared a markerless system (SPLYZA Motion) with optical motion capture (OptiTrack) during single-leg squat (SQ; 15 patients) and single-leg drop-jump landing (DJL; seven patients) after ACL reconstruction. Sagittal- and frontal-plane angles were analyzed from lateral and anterior camera views, respectively; thus, accuracy reflects view-specific conditions. Root mean square error (RMSE), intraclass correlation coefficients (ICC(A,1)) for range of motion (ROM), and waveform Pearson correlations (r) were evaluated for five joint rotations. Without offset correction, ICC values were 0.78–0.93 for hip and knee flexion/extension, 0.47–0.79 for ankle dorsiflexion/plantarflexion, and 0.03–0.30 for hip adduction/abduction and knee varus/valgus. Pearson’s r values were 0.77–0.99 for sagittal-plane rotations and 0.07–0.58 for frontal-plane rotations. Trial-specific offset correction reduced RMSE without changing ROM-based ICC, but the RMSE improvement was largely lost when offsets were estimated from other participants. Markerless analysis shows clinical potential for sagittal-plane ROM during SQ and hip flexion/extension during DJL, whereas other measurements, particularly frontal-plane ROM, require caution.

The authors' abstract, as published at the source. Sensors, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Surgery

SurgeryMedicine