PofoliaDaily literature tracker

Medical Image Analysis· 2026Q1

The autoPET3 challenge: Automated lesion segmentation in whole-body PET/CT — Multitracer multicenter generalization

Jakob Dexl, Katharina Jeblick, Andreas Mittermeier, Balthasar Maria Schachtner et al.

Short summary

The autoPET3 challenge benchmarked automated lesion segmentation in whole-body PET/CT, with the top algorithm achieving a mean Dice Similarity Coefficient (DSC) of 0.66 and improving DSC by 8% over the baseline.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The autoPET3 challenge benchmarked automated lesion segmentation in whole-body PET/CT.
  • The largest annotated PSMA PET/CT dataset to date was utilized.
  • The top algorithm achieved a mean DSC of 0.66, an 8% improvement over the baseline.
  • Generalization to unseen tracer-center combinations is an open problem, driven by systematic volume overestimation.

AI-generated from the title and abstract; the full text is not read.

Abstract

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1014 [ 18 F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [ 18 F]/[ 68 Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer–center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category restricted participants to a fixed baseline model to isolate data handling strategies. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5 mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and likely approaching reader agreement; (2) compositional generalization to unseen tracer–center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.

The authors' abstract, as published at the source. Medical Image Analysis, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Computer Vision and Pattern Recognition

Computer Vision and Pattern RecognitionComputer Science