Materials Chemistry and Physics· 2026Q1
Radiopaque PCL–BaSO4 composites for extrusion-based 3D printing of endovascular device-like structures
- 1citations
- Q1SCImago
- 2026year
Short summary
Researchers developed radiopaque poly(ε-caprolactone) (PCL) composites by incorporating barium sulfate (BaSO4) for 3D printing of endovascular devices, achieving clinically relevant contrast (ΔHU > 250) with 10 wt% BaSO4 (PCL-R10) without compromising mechanical integrity or endothelial cell viability.
AI-generated from the title and abstract; the full text is not read.
Key points
- Radiopaque PCL composites with BaSO4 were developed for 3D printing of endovascular device structures.
- The 10 wt% BaSO4 formulation (PCL-R10) achieved clinically relevant contrast (ΔHU > 250) for fluoroscopy and CT.
- BaSO4 incorporation did not compromise the mechanical integrity or radial strength of the PCL composites.
- Endothelial cell viability remained above the ISO 10993-5 threshold, indicating good cytocompatibility.
AI-generated from the title and abstract; the full text is not read.
Abstract
Poly(ε-caprolactone) (PCL) is a biodegradable thermoplastic polymer with promising properties for bioresorbable endovascular devices. However, among other limitations, its intrinsic radiolucency limits intraoperative visualization during fluoroscopy- and computed tomography-guided vascular interventions. To address this limitation, radiopaque PCL composites containing barium sulfate (BaSO 4 ) were developed and processed via extrusion-based 3D printing into endograft-inspired ring structures. This study therefore addresses a specific question: whether BaSO 4 can be incorporated into extrusion-printable PCL to achieve clinically relevant fluoroscopic and CT visibility in endovascular device-like structures without compromising mechanical integrity or endothelial cytocompatibility, and whether these three domains can be assessed within a single, accessible screening workflow. Radiopacity was quantitatively evaluated by micro-computed tomography under both in vitro and ex vivo conditions using porcine aortic segments. Increasing BaSO 4 concentration produced a concentration-dependent enhancement in radiographic visibility, with the 10 wt% formulation (PCL-R10) achieving clinically relevant contrast relative to surrounding vascular tissue (ΔHU > 250), enabling unambiguous segmentation under tissue-mimicking conditions. Mechanical performance was assessed through uniaxial compression testing within a clinically relevant oversizing range (10–20% diameter reduction). No significant differences in radial mechanical response were observed following BaSO 4 incorporation, indicating preservation of structural integrity despite enhanced radiopacity. Cytocompatibility was assessed on human umbilical vein endothelial cells (HUVECs) exposed to conditioned media prepared according to ISO 10993-12, using the Trypan Blue exclusion assay and LIVE/DEAD staining at 72 h and 7 days. Relative cell viability remained above the 70%-of-control threshold defined by ISO 10993-5 for all formulations and at both timepoints, and viable cell numbers did not differ significantly from control. Overall, these findings demonstrate that BaSO 4 incorporation enables clinically meaningful radiopacity in extrusion-printable PCL composites without compromising mechanical functionality or endothelial cytocompatibility. The proposed approach supports the development of fluoroscopically visible bioresorbable endovascular implants and provides a practical multi-domain evaluation strategy for radiopaque biodegradable materials.
The authors' abstract, as published at the source. Materials Chemistry and Physics, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Biomaterials
BiomaterialsMaterials Science