PeerJ· 2026Q1
Influence of obturation technique and sealer type on the fracture resistance of maxillary central incisors with simulated traumatic fractures
- 0citations
- Q1SCImago
- 2026year
Short summary
TotalFill BC sealer significantly increased fracture resistance in endodontically treated maxillary central incisors with simulated traumatic fractures compared to AH Plus, regardless of obturation technique (single-cone vs. warm vertical compaction).
AI-generated from the title and abstract; the full text is not read.
Key points
- TotalFill BC sealer resulted in higher fracture resistance values than AH Plus sealer in endodontically treated incisors.
- Both obturation technique (single-cone vs. warm vertical compaction) and sealer type significantly affected fracture resistance.
- No significant interaction was observed between obturation technique and sealer type.
- The single-cone technique combined with TotalFill BC showed the highest numerical mean fracture load.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background This study evaluated the effects of obturation technique and sealer type on the fracture resistance of endodontically treated maxillary central incisors with simulated traumatic crown fractures under clinically relevant loading conditions. Methods Forty extracted human maxillary central incisors were randomly assigned to either the single-cone technique or warm vertical compaction technique. Each group was further divided according to the sealer used: AH Plus or TotalFill BC. After obturation, the crowns were restored with a short fiber-reinforced composite and a nanohybrid composite resin. The specimens were stored at 100% humidity for two weeks and embedded in acrylic resin. Fracture resistance was assessed using a universal testing machine with oblique loading at 45°. The data were analyzed using two-way analysis of variance (ANOVA) at a significance level of 0.05. Results Both obturation technique and sealer type significantly affected fracture resistance. TotalFill BC produced higher fracture-load values than AH Plus, while the single-cone technique (SCT)/TotalFill BC group had the highest numerical mean. However, no significant interaction was found between obturation technique and sealer type. Conclusions Within the limitations of this in vitro study, sealer selection emerged as the primary factor influencing fracture resistance. TotalFill BC provided greater fracture resistance than AH Plus across both obturation techniques, while the absence of a significant interaction indicated that neither technique conferred a sealer-specific advantage.
The authors' abstract, as published at the source. PeerJ, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Orthodontics
OrthodonticsDentistry