PofoliaShared via Pofolia

International Journal of Dental Hygiene· 2026Q2

Does Hydrogen Peroxide/Colloidal‐Silver Reduce the Aerosolized Bacteria Generated During Dental Procedures?

Ayşe BULUT, S. Ozsoy, Gülçin Akca, Nazime Tuncay et al.

Short summary

A 500 ppm hydrogen peroxide/colloidal silver solution significantly reduced aerosolized Staphylococcus aureus contamination by up to 99% at distances of 50-200 cm compared to sterile water (p < 0.001).

AI-generated from the title and abstract; the full text is not read.

Key points

  • A 500 ppm H2O2/colloidal silver solution was tested against sterile water in a dental aerosol model.
  • Bacterial contamination (Staphylococcus aureus) was measured using colony-forming units (CFU)/plate.
  • Significant reductions in bacterial counts were observed at 50, 100, and 200 cm distances at the 6 o'clock position (p < 0.001).
  • Reductions were also significant at 100 and 200 cm at the 9 o'clock position (p < 0.001).
  • A notable reduction was observed at the head position in the H2O2/colloidal silver group.

AI-generated from the title and abstract; the full text is not read.

Abstract

ABSTRACT Objectives Bioaerosols containing live microorganisms that may cause disease development are formed during many dental procedures. Although some recent studies have addressed reduction of the aerosolized bacterial load, none have examined the use of hydrogen peroxide (H 2 O 2 )/colloidal‐silver for this purpose. The current study aimed to evaluate the reduction of aerosolized bacteria during dental procedures at different distances and directions and investigate the efficacy of H 2 O 2 /Colloidal‐silver on Staphylococcus aureus . Methods Group A ( n = 300) was the control group where sterile distilled water was used. Group B ( n = 300) was the study group, where sterile distilled water with 500 ppm H 2 O 2 /Colloidal‐silver was used. Blood agar plates were placed at the 3, 6, and 9 o'clock positions and the head position (relative to 12 o'clock) at different distances; the head phantom's jaws were then contaminated with bacterial suspension at each position. The plates were then incubated for 24–48 h. The grown colonies were counted and expressed as colony‐forming units (CFU)/plate. Statistical analysis was performed using the Mann–Whitney U test for comparing independent samples. Results There were statistically significant differences between Group A and Group B bacterial counts at 50, 100, and 200 cm distances at the 6 o'clock position, and at 100 and 200 cm distances at the 9 o'clock position ( p < 0.001, remaining significant after Bonferroni correction). There was a notable reduction in Group B at the head position compared to Group A. Conclusion The findings showed that H 2 O 2 /Colloidal‐silver (0.05%) had bactericidal efficacy against settled Staphylococcus aureus contamination at the positions tested.

The authors' abstract, as published at the source. International Journal of Dental Hygiene, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: General Dentistry

General DentistryDentistry