Journal of NeuroInterventional Surgery· 2026Q1
Simüle Edilmiş Nörovasküler Girişimler Sırasında Mikroplastik, Nanoplastik ve PFAS'ın İş Akışı Düzeyinde Salınımı
Workflow level release of microplastics, nanoplastics, and perfluoroalkyl and polyfluoroalkyl substances during simulated neurovascular interventions
- 1atıf
- Q1SCImago
- 2026yıl
Kısa özet
Simüle edilmiş nörovasküler girişimler, prosedür sıvısına mikroplastikler (MP'ler), nanoplastikler (NP'ler) ve perfluoroalkil ve polifloroalkil maddeler (PFAS) saldı; ortalama MP partikül sayısı 15 partikül/örnek, ortalama NP konsantrasyonu 18,19 µg/L ve ortalama toplam PFAS 127 µg/L olarak ölçüldü.
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Ana noktalar
- Simüle edilmiş nörovasküler girişimler, prosedür sıvısına MP, NP ve PFAS saldı.
- Ortalama MP partikül sayısı 15 partikül/örnek (IQR 9.0–27.3) idi.
- Ortalama NP konsantrasyonu 18,19 µg/L (IQR 5.85–33.35) idi.
- Ortalama toplam PFAS konsantrasyonu 127 µg/L (IQR 93.5–272.0) idi.
- PFAS seviyeleri trombektomiye kıyasla anevrizma simülasyonlarında daha yüksekti (ortalama 209,5'e karşı 98,0 µg/L).
Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.
Özet (abstract)
Background Catheter based neurovascular interventions rely on polymer based, coated, and fluorinated devices. Mechanical manipulation may release particulate and molecular contaminants, but integrated workflow level quantification of microplastic (MP), nanoplastic (NP), and perfluoroalkyl and polyfluoroalkyl substance (PFAS) release during neurovascular procedures remains limited. This study quantified MP, NP, and PFAS release in an in vitro simulation of neurointerventional workflows. Methods 20 neurovascular procedures were simulated under standardized in vitro conditions, including 10 mechanical thrombectomy and 10 aneurysm treatment workflows. Procedures were performed in 5 L glass containers using warmed saline, contrast medium, and clinically applied neurovascular devices. Procedural fluid was collected after each simulation and aliquoted for MP, NP, and PFAS analysis using micro-Fourier transform infrared spectroscopy, pyrolysis–gas chromatography–mass spectrometry, and ultra high performance liquid chromatography–tandem mass spectrometry, respectively. Results Contaminants were detected across all simulated procedures. Median MP particle count was 15 particles per analyzed sample volume (IQR 9.0–27.3; range 0–58), median NP concentration was 18.19 µg/L (IQR 5.85–33.35; range 2.19–1671.10), and median sum PFAS concentration was 127 µg/L (IQR 93.5–272.0; range 47–458). MP and NP levels did not differ between thrombectomy and aneurysm simulations. Sum PFAS concentrations were higher during thrombectomy than during aneurysm treatment simulations (median 209.5 vs 98.0 µg/L; P=0.010), particularly in stent retriever compared with direct aspiration simulations (median 287.0 vs 120.0 µg/L; P=0.030). NP and sum PFAS concentrations were strongly correlated (ρ=0.689; P=0.001). Conclusions Simulated neurovascular interventions generated measurable release of MP, NP, and PFAS into procedural fluid. Workflow level assessment may support future source specific testing, clinical validation, and material safety evaluation.
Yazarların özeti; kaynağından alınmıştır. Journal of NeuroInterventional Surgery, 2026 · DOI ↗
Ücretsiz hesapla devam et
Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.
Web'de ücretsiz devam etGoogle ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.
Telefonda:
Alan: Göğüs ve Solunum Tıbbı
Pulmonary and Respiratory MedicineMedicine