PofoliaShared via Pofolia

BMC Oral Health· 2026Q1

Influence of arch form on the accuracy of digital workflow in all-on-four implant rehabilitation cases (an in vitro study)

Mohamed S. Torky, Rewaa G. AboElHassan, Amir S. Azer

Short summary

Tapered arch forms yield the highest trueness and precision in digital scans for All-on-4 implant cases, with the wave scanning strategy also improving precision.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Tapered arch forms demonstrated the highest trueness and precision in digital scans for All-on-4 implant rehabilitation.
  • The wave scanning strategy significantly improved the precision of digital impressions.
  • Arch form and scanning strategy did not show a significant interaction effect on scan accuracy.
  • All tested arch forms and scanning strategies produced results within clinically acceptable thresholds for passive prosthetic fit.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Background Variations in arch form may influence the accuracy of digital impressions for implant-retained fixed dental prostheses. Differences in arch width, curvature, and span length can affect scanning continuity and data stitching, potentially impacting trueness and precision during full-arch acquisition. However, the extent to which arch form and scanning strategy interact to influence digital impression accuracy remains unclear. Purpose The purpose of this in vitro study was to evaluate the effect of arch form on the accuracy of the digital work flow of implant-retained fixed dental prostheses. Methods Three maxillary edentulous full-arch models with different forms—ovoid (O), tapered (T), and square (S)—were 3D printed. Four implants were placed in each model and loaded with scan bodies. Reference scans were obtained using a high-precision laboratory scanner. Each model was scanned with a Medit i700 intraoral scanner (IOS) using three scanning strategies Linear (L), S-curve (S), and Wave (W). Each strategy was performed 10 times per model, generating 90 STL files. Trueness and precision were evaluated using Geomagic Control X software and statistically analyzed (α = 0.05). Results Arch form significantly influenced trueness ( p < 0.001), with the tapered arch demonstrating the highest trueness, followed by square and ovoid forms. Precision was significantly affected by arch form ( p < 0.001) and scanning strategy ( p = 0.006). The wave strategy showed significantly greater precision than the other strategies. No significant interaction was found between arch form and scanning strategy ( p = 0.769). Conclusion Within the limitations of this in vitro study, Arch morphology and scanning strategy significantly impact both the trueness and precision of full-arch implant scans. While tapered arches demonstrated statistically highest trueness and precision and the wave scanning strategy maximized precision, all tested combinations remained safely within the clinically acceptable threshold for passive prosthetic fit.

The authors' abstract, as published at the source. BMC Oral Health, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthodontics

OrthodonticsDentistry