Langmuir· 2026Q1
Nitrogen- and Sulfur-Co-Doped Reduced Graphene Oxide-Based Antifouling Electrochemical Sensor for the Detection of l -Tyrosine
- 0citations
- Q1SCImago
- 2026year
Short summary
A nitrogen- and sulfur-co-doped reduced graphene oxide (NS-rGO) modified electrode effectively detects l-tyrosine while resisting electrode fouling from biomolecules.
AI-generated from the title and abstract; the full text is not read.
Key points
- Nitrogen- and sulfur-co-doped reduced graphene oxide (NS-rGO) was used to modify a glassy carbon electrode (GCE).
- The NS-rGO/GCE exhibited enhanced electrocatalytic activity for l-tyrosine detection.
- The modified electrode showed resistance to fouling, maintaining a stable current response for 120 minutes in the presence of bovine serum albumin (BSA).
- The sensor achieved a limit of detection of 0.23 ± 0.02 μM and a sensitivity of 0.457 ± 0.01 μA μM–1 cm–2.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Electrochemical sensing of l-tyrosine is challenging because its oxidation products and other biomolecules can adsorb onto the electrode surface, resulting in electrode fouling and deterioration of sensing performance. To address this limitation, nitrogen- and sulfur-co-doped reduced graphene oxide (NS-rGO) is proposed as a dual-functional antifouling and electrocatalytic platform for l-tyrosine sensing. In this work, NS-rGO was used to modify the glassy carbon electrode (GCE), and its electrochemical performance was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The introduction of N and S heteroatoms into the rGO framework provides an electrode surface that combines enhanced electrocatalytic activity with improved resistance to non-specific surface adsorption. The NS-rGO/GCE exhibited enhanced electrocatalytic activity towards l-tyrosine and effectively suppressed fouling caused by its oxidation products. Furthermore, the modified electrode maintained a stable current response even after 120 min of exposure to bovine serum albumin (BSA), demonstrating its ability to retain its sensing performance under a protein-rich fouling environment. The limit of detection of the sensor was found to be 0.23 ± 0.02 μM, with a sensitivity of 0.457 ± 0.01 μA μM–1 cm–2 (n = 3). These findings demonstrate the significance of NS-rGO as an antifouling sensing interface that can simultaneously address electrocatalytic activity and electrode fouling, providing a promising strategy for more stable electrochemical detection of l-tyrosine in complex matrices.
The authors' abstract, as published at the source. Langmuir, 2026 · DOI ↗