PofoliaShared via Pofolia

BMC Oral Health· 2026Q1

Can preheated resin composite optimize bond strength and film thickness for indirect adhesive restorations?

Sevde Kursun, Neslihan Tekçe, Safa Tuncer, Mustafa Demırcı

Short summary

Preheating resin composite to lute indirect restorations yielded bond strength comparable to dual-cure resin cement, but film thickness remained above the clinically acceptable limit.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Preheated resin composite demonstrated bond strength comparable to dual-cure resin cement for indirect restorations.
  • Both preheated and room-temperature resin composite groups showed similar bond strength values.
  • Preheating resin composite significantly reduced its film thickness compared to room-temperature application.
  • The film thickness of preheated resin composite remained above the clinically acceptable limit.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Purpose Resin composite shows potential as a luting agent for indirect adhesive restorations, but its viability as an alternative to resin cement remains uncertain. This study aimed to evaluate the microtensile bond strength (µTBS) and film thickness of preheated resin composite used as a luting agent for indirect adhesive restorations. Materials and methods Fifteen extracted molars were randomly assigned to three groups ( N = 15): dual-cure resin cement (control group), room-temperature resin composite, and preheated resin composite. After the resin blocks were luted with dual-cure resin cement or resin composite, based on the assigned groups, the specimens ( n = 75) underwent µTBS testing. Film thickness evaluation ( n = 72) was performed by measuring the cement layer thickness of sections under a stereomicroscope. Data were analyzed using one-way ANOVA, Tukey, Kruskal-Wallis, and Dunn tests. Results The dual-cure resin cement exhibited higher bond strength than the room-temperature resin composite but showed bond strength comparable to that of the preheated resin composite. Both resin composite groups (preheated and room-temperature) showed similar bond strength values. The film thickness test revealed that the resin cement had the thinnest film layer, followed by the preheated resin composite. The highest film thickness was observed in the room-temperature resin composite. Although preheating did not significantly affect bond strength, it reduced the film thickness. Conclusion For the luting of indirect restorations, preheated resin composite exhibited bond strength comparable to that of dual-cure resin cement. Preheating reduced the film thickness of the resin composite luting layer; however, even when preheated, the film thickness remained above the clinically acceptable limit.

The authors' abstract, as published at the source. BMC Oral Health, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthodontics

OrthodonticsDentistry