Short summary

Corrosion degrades precast concrete connections more severely than monolithic elements, with current design codes lacking specific guidance for assessment.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Corrosion causes more severe degradation in precast connections compared to monolithic concrete elements.
  • Key structural parameters affected include load-carrying capacity, moment-rotation, deflection, and stiffness.
  • Current design codes (ACI 318-19, Eurocode 2) lack specific guidance for assessing corroded precast connections.
  • Extrapolating data from monolithic concrete to precast connections is non-conservative.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Precast concrete offers significant advantages in modern construction, but its long-term performance is critically governed by the durability of its connections. These connections act as preferential sites for reinforcement corrosion, making them the most vulnerable components in precast structures. While extensive research exists on corrosion in monolithic concrete, a significant knowledge gap persists for precast connections. This state-of-the-art review synthesizes literature on the structural performance of corroded precast connections. It evaluates how corrosion impacts key parameters, including load-carrying capacity, moment–rotation, deflection, and stiffness and discusses practical mitigation, inspection, and repair strategies. The review establishes that degradation is consistently more severe in precast connections than in monolithic elements due to localized interface effects. Further, significant deficiencies in design codes [e.g., ACI 318-19 (ACI 2019) and Eurocode 2 (CEN 2011)] are identified, as they lack specific guidance for assessing corroded connections. The findings underscore the nonconservative nature of extrapolating monolithic data and highlight the need for research on tailored testing, modeling, and design guidelines for precast infrastructure.

The authors' abstract, as published at the source. Journal of structural design and construction practice., 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account