PofoliaShared via Pofolia

International Orthodontics· 2026Q1· Review

Over-insertion of orthodontic mini-implants in the maxilla: A systematic review of maxillary sinus, nasal floor and incisive canal perforations

Lars Stucki, Hermann Schuster, Julia Schwab, Andreas Hoenigl et al.

Short summary

Maxillary mini-implant over-insertion is common, with sinus perforation occurring in 8-78.3% of cases and incisive canal/nasal floor perforation in up to 25% and 21.2% of subjects, respectively.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Maxillary sinus perforation occurred in 8-78.3% of 702 OMIs, with penetration depths up to 3.23 mm.
  • Sinus floor thickness < 6 mm increased perforation risk 21.63-fold; penetration > 1 mm thickened the membrane.
  • Incisive canal perforation affected 25% of subjects, and nasal floor perforation affected 21.2% of subjects.
  • Risk factors include sinus floor thickness, screw length, insertion angle, age, and anterior crowding.

AI-generated from the title and abstract; the full text is not read.

Abstract

Objective Orthodontic mini-implants (OMIs) provide skeletal anchorage but may be over-inserted, perforating the maxillary sinus, nasal cavity, or incisive canal. This systematic review evaluated the frequency and consequences of such over-insertion in the maxilla. Methods This systematic review was registered in PROSPERO (CRD420261377587) and followed PRISMA guidelines. PubMed, Livivo, Cochrane, and Google Scholar were searched for studies reporting prevalence and complications of maxillary OMI over-insertion. Of 98 records, 7 studies were included. Two reviewers independently selected and extracted data, and methodological quality was assessed using Joanna Briggs Institute tools. Results Across the included studies comprising 702 OMIs, maxillary sinus perforation ranged from 8 to 78.3%, with mean penetration depths between 0.79 and 3.23 mm. In a cadaver model, sinus perforation increased from 0% with 6-mm screws to 10% with 8-mm and 15% with 10-mm screws. Penetration > 1 mm raised Schneiderian membrane thickening from 37.5 to 88.2%, with a mean increase of 0.6 mm, but no clinical sinusitis was reported. A sinus floor thickness < 6 mm markedly increased penetration risk (odds ratio 21.63). For anterior palatal OMIs, incisive canal perforation affected 25% of subjects (13.5% of OMIs), and nasal floor perforation up to 21.2% of subjects (11.5% of OMIs), with mean depth 1.4 ± 0.4 mm (range 0.5–2.0 mm). One oronasal fistula after osseointegrated palatal implant explantation was the only severe complication. Conclusions Radiographic perforations are relatively frequent, and risk is influenced by sinus floor thickness, screw length, insertion angle, age, and anterior crowding. Although these perforations are usually clinically asymptomatic, cautious length selection and 3D-based planning are recommended to minimize avoidable tissue reactions.

The authors' abstract, as published at the source. International Orthodontics, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Orthodontics

OrthodonticsDentistry