Kritik Hastalarda Santral Venöz Basıncı Tahmini İçin Yeni Bir Nokta Bakım Ultrason Yönteminin Doğrulanması

Validation of a Novel Point‐of‐Care Ultrasound Method for Estimating Central Venous Pressure in Critically Ill Patients

Carmelo José Espinosa‐Almanza, Jorge Leonardo Támara-Rivera, Hector Andrés Ruíz-Ávila

Kısa özet

Yeni bir nokta bakım ultrason yöntemi (CVPus), kritik hastalarda santral venöz basıncı (CVP) orta derecede korelasyon (r=0.61) ve iyi ayırt edici yetenekle (CVP ≥10 mmHg için AUC 0.83) tahmin edebilmektedir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • Yeni bir ultrason yöntemi (CVPus), 75 kritik hastanın 70'inde uygulanabilir bulunmuştur.
  • CVPus, invaziv CVP ile orta derecede pozitif korelasyon (r=0.61, p < .001) göstermiştir.
  • CVPus ve invaziv CVP arasındaki ortalama yanlılık -0.33 mmHg olup, %95 güven aralığı -6.37 ile 5.72 mmHg arasındadır.
  • Yöntem, CVP ≥5 mmHg (AUC 0.81) ve CVP ≥10 mmHg (AUC 0.83) eşik değerleri için iyi bir ayırt edici performans sergilemiştir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

OBJECTIVES: To validate an ultrasound-based method for noninvasive estimation of central venous pressure (CVP) in critically ill patients and compare its performance with invasively measured CVP. METHODS: We conducted an analytical cross-sectional study in adults admitted to a general intensive care unit. Patients with a central venous catheter and CVP monitoring through an electronic transducer were included. Ultrasound-estimated CVP (CVPus) was calculated using the method described by Istrail et al, which combines right atrial depth and jugular venous distension height. Correlation, paired mean differences, Bland-Altman agreement, and discriminative performance for invasive CVP thresholds of ≥5 and ≥10 mmHg were assessed. RESULTS: Seventy-five patients were included; CVPus was feasible in 70. Mean invasive CVP was 5.50 ± 3.80 mmHg; 53.3% of patients had CVP ≥5 mmHg and 21.3% had CVP ≥10 mmHg. CVPus showed a moderate positive correlation with invasive CVP (r = 0.61; p < .001). Mean invasive CVP and mean CVPus were 5.26 and 5.59 mmHg, respectively (p = .375). Bland-Altman analysis showed a mean bias of -0.33 mmHg, with 95% limits of agreement from -6.37 to 5.72 mmHg. The area under the ROC curve was 0.83 (95% CI, 0.68-0.99) for invasive CVP ≥10 mmHg and 0.81 (95% CI, 0.71-0.91) for invasive CVP ≥5 mmHg. CONCLUSIONS: The Istrail et al ultrasound method showed favorable overall performance for noninvasive CVP estimation in critically ill patients. Its low mean bias and good discriminative ability support its use as a complementary bedside tool, although agreement with invasive measurement remains limited.

Yazarların özeti; kaynağından alınmıştır. Journal of Ultrasound in Medicine, 2026 · DOI ↗