PofoliaShared via Pofolia

Ophthalmology· 2014Q1· Clinical trial

Three-Year, Randomized, Sham-Controlled Trial of Dexamethasone Intravitreal Implant in Patients with Diabetic Macular Edema

David S. Boyer, Young Hee Yoon, Rubens Belfort, Francesco Bandello et al.

Short summary

A three-year trial found that dexamethasone intravitreal implants (Ozurdex) at both 0.7 mg and 0.35 mg doses significantly improved visual acuity and reduced retinal thickness in patients with diabetic macular edema compared to sham treatment.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Dexamethasone implants (0.7 mg and 0.35 mg) improved visual acuity by at least 15 letters in 22.2% and 18.4% of patients, respectively, versus 12.0% for sham.
  • Implants significantly reduced central retinal thickness by over 100 μm compared to approximately 40 μm for sham.
  • Cataract-related adverse events were substantially higher in implant groups (67.9% and 64.1%) than sham (20.4%).
  • Most intraocular pressure increases were manageable, with only 0.6% and 0.3% requiring surgery.

AI-generated from the title and abstract; the full text is not read.

Abstract

PURPOSE: To evaluate the safety and efficacy of dexamethasone intravitreal implant (Ozurdex, DEX implant) 0.7 and 0.35 mg in the treatment of patients with diabetic macular edema (DME). DESIGN: Two randomized, multicenter, masked, sham-controlled, phase III clinical trials with identical protocols were conducted. Data were pooled for analysis. PARTICIPANTS: Patients (n = 1048) with DME, best-corrected visual acuity (BCVA) of 20/50 to 20/200 Snellen equivalent, and central retinal thickness (CRT) of ≥300 μm by optical coherence tomography. METHODS: Patients were randomized in a 1:1:1 ratio to study treatment with DEX implant 0.7 mg, DEX implant 0.35 mg, or sham procedure and followed for 3 years (or 39 months for patients treated at month 36) at ≤40 scheduled visits. Patients who met retreatment eligibility criteria could be retreated no more often than every 6 months. MAIN OUTCOME MEASURES: The predefined primary efficacy endpoint for the United States Food and Drug Administration was achievement of ≥15-letter improvement in BCVA from baseline at study end. Safety measures included adverse events and intraocular pressure (IOP). RESULTS: Mean number of treatments received over 3 years was 4.1, 4.4, and 3.3 with DEX implant 0.7 mg, DEX implant 0.35 mg, and sham, respectively. The percentage of patients with ≥15-letter improvement in BCVA from baseline at study end was greater with DEX implant 0.7 mg (22.2%) and DEX implant 0.35 mg (18.4%) than sham (12.0%; P ≤ 0.018). Mean average reduction in CRT from baseline was greater with DEX implant 0.7 mg (-111.6 μm) and DEX implant 0.35 mg (-107.9 μm) than sham (-41.9 μm; P < 0.001). Rates of cataract-related adverse events in phakic eyes were 67.9%, 64.1%, and 20.4% in the DEX implant 0.7 mg, DEX implant 0.35 mg, and sham groups, respectively. Increases in IOP were usually controlled with medication or no therapy; only 2 patients (0.6%) in the DEX implant 0.7 mg group and 1 (0.3%) in the DEX implant 0.35 mg group required trabeculectomy. CONCLUSIONS: The DEX implant 0.7 mg and 0.35 mg met the primary efficacy endpoint for improvement in BCVA. The safety profile was acceptable and consistent with previous reports.

The authors' abstract, as published at the source. Ophthalmology, 2014 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Ophthalmology

OphthalmologyMedicine