PofoliaShared via Pofolia

Engineering Structures· 2026Q1

Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures

Chipui Chao, Ran Ding, Hong‐Ming Lu, Xin Nie et al.

Short summary

Reverse bulb flat shear connectors exhibit significantly enhanced shear performance compared to normal types in composite structures, with their behavior governed by concrete splitting from bulb ends.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Reverse bulb flat shear connectors show superior shear performance compared to normal bulb flat types.
  • T-shaped and reverse bulb flat connectors fail via concrete crushing in the web root.
  • Normal bulb flat connectors fail by splitting along cracks from the bulb ends.
  • Modified design formulas accurately predict shear stiffness and capacity for T-shaped and bulb flat connectors.

AI-generated from the title and abstract; the full text is not read.

Abstract

This study investigates the mechanical performance and theoretical design methods of T-shaped and bulb flat shear connectors in large-scale steel-concrete composite structures. The full-scale push-out test were conducted, including 9 groups of T-shaped and 6 groups of bulb flat shear connectors. The failure modes, crack development patterns, stress distributions, shear force-relative displacement relationships were analyzed across the specimen groups. Experimental results demonstrate that the shear behavior of T-shaped and reverse bulb flat shear connectors is governed by the crushing of non-reinforced concrete in the web root region under stress concentration, whereas that of normal bulb flat shear connectors is controlled by splitting along crack propagation from the bulb ends. Furthermore, reverse bulb flat shear connectors exhibit significantly enhanced shear performance compared to normal types under identical design conditions. Incorporating the superimposed contribution of compressive concrete adjacent to the flange or bulb, modified design methods applicable to T-shaped and bulb flat shear connectors are proposed based on the elastic foundation beam models for normal L-shaped shear connectors. Validated against experimental results, these formulas can accurately estimate the shear stiffness and capacity of the two types of connectors.

The authors' abstract, as published at the source. Engineering Structures, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Civil and Structural Engineering