PofoliaShared via Pofolia

Nature· 2026Q1

Lu+ optical frequency references with accuracy verified at the 19th digit

K. J. Arnold, Michael Dao Kang Lee, Qi Zhao, Qichen Qin et al.

Short summary

Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Two independent 176Lu+ single-ion optical clocks were created with fractional frequency uncertainties near 1 × 10−19.
  • A direct comparison using correlation spectroscopy demonstrated agreement between the clocks at a relative frequency difference of (5.7)stat × 10−19.
  • The clocks achieve evaluated uncertainties below 10−18, verified by a same-species comparison to the 5.7 × 10−19 level.
  • These room-temperature systems advance precision timekeeping and enable tests of fundamental physics.

AI-generated from the title and abstract; the full text is not read.

Abstract

Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.

The authors' abstract, as published at the source. Nature, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Atomic and Molecular Physics, and Optics

Atomic and Molecular Physics, and OpticsPhysics and Astronomy