PofoliaShared via Pofolia

IEEE Transactions on Medical Imaging· 2016Q1

Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?

Nima Tajbakhsh, J. Shin, Suryakanth Gurudu, R. Todd Hurst et al.

Short summary

Fine-tuning pre-trained deep convolutional neural networks (CNNs) consistently matches or surpasses training from scratch for medical image analysis, even with limited data.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Fine-tuned pre-trained CNNs match or outperform CNNs trained from scratch in medical imaging tasks.
  • Fine-tuned CNNs are more robust to variations in training set size.
  • The optimal fine-tuning strategy (shallow vs. deep) varies by application.
  • A layer-wise fine-tuning scheme can optimize performance based on available data.

AI-generated from the title and abstract; the full text is not read.

Abstract

Training a deep convolutional neural network (CNN) from scratch is difficult because it requires a large amount of labeled training data and a great deal of expertise to ensure proper convergence. A promising alternative is to fine-tune a CNN that has been pre-trained using, for instance, a large set of labeled natural images. However, the substantial differences between natural and medical images may advise against such knowledge transfer. In this paper, we seek to answer the following central question in the context of medical image analysis: Can the use of pre-trained deep CNNs with sufficient fine-tuning eliminate the need for training a deep CNN from scratch? To address this question, we considered four distinct medical imaging applications in three specialties (radiology, cardiology, and gastroenterology) involving classification, detection, and segmentation from three different imaging modalities, and investigated how the performance of deep CNNs trained from scratch compared with the pre-trained CNNs fine-tuned in a layer-wise manner. Our experiments consistently demonstrated that 1) the use of a pre-trained CNN with adequate fine-tuning outperformed or, in the worst case, performed as well as a CNN trained from scratch; 2) fine-tuned CNNs were more robust to the size of training sets than CNNs trained from scratch; 3) neither shallow tuning nor deep tuning was the optimal choice for a particular application; and 4) our layer-wise fine-tuning scheme could offer a practical way to reach the best performance for the application at hand based on the amount of available data.

The authors' abstract, as published at the source. IEEE Transactions on Medical Imaging, 2016 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiology, Nuclear Medicine and Imaging

Radiology, Nuclear Medicine and ImagingMedicine