Magnetic Resonance in Medicine· 2014Q1· Review
Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia
- 2,222citations
- Q1SCImago
- 2014year
Short summary
A consensus statement recommends pseudo-continuous labeling, background suppression, and a 3D readout for arterial spin-labeled (ASL) perfusion MRI, enabling standardized clinical application and calculation of cerebral blood flow in absolute units.
AI-generated from the title and abstract; the full text is not read.
Key points
- ASL perfusion MRI is recommended for clinical use with a standardized approach.
- The consensus favors pseudo-continuous labeling and background suppression.
- A segmented 3D readout is recommended without vascular crushing gradients.
- Cerebral blood flow should be calculated in absolute units using a simplified model.
AI-generated from the title and abstract; the full text is not read.
Abstract
This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ASL in Dementia consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this review, we describe the major considerations and trade-offs in implementing an ASL protocol and provide specific recommendations for a standard approach. Our conclusion is that as an optimal default implementation, we recommend pseudo-continuous labeling, background suppression, a segmented three-dimensional readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model.
The authors' abstract, as published at the source. Magnetic Resonance in Medicine, 2014 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Radiology, Nuclear Medicine and Imaging
Radiology, Nuclear Medicine and ImagingMedicine