PofoliaShared via Pofolia

npj Digital Medicine· 2018Q1

Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices

Michael D. Abràmoff, Philip T. Lavin, Michele Birch, Nilay Shah et al.

Short summary

An autonomous AI system achieved 87.2% sensitivity and 90.7% specificity in detecting more than mild diabetic retinopathy (mtmDR) in a pivotal trial, leading to its FDA authorization as the first autonomous AI diagnostic system in medicine.

AI-generated from the title and abstract; the full text is not read.

Key points

  • The AI system detected more than mild DR with 87.2% sensitivity and 90.7% specificity in a trial of 900 primary care patients.
  • The system achieved a 96.1% imageability rate, demonstrating its practical utility.
  • These findings supported the FDA authorization of the AI system, the first autonomous AI diagnostic system approved in any medical field.
  • The AI system brings specialty-level diagnostics to primary care, with the potential to prevent vision loss in thousands of diabetic patients annually.

AI-generated from the title and abstract; the full text is not read.

Abstract

Artificial Intelligence (AI) has long promised to increase healthcare affordability, quality and accessibility but FDA, until recently, had never authorized an autonomous AI diagnostic system. This pivotal trial of an AI system to detect diabetic retinopathy (DR) in people with diabetes enrolled 900 subjects, with no history of DR at primary care clinics, by comparing to Wisconsin Fundus Photograph Reading Center (FPRC) widefield stereoscopic photography and macular Optical Coherence Tomography (OCT), by FPRC certified photographers, and FPRC grading of Early Treatment Diabetic Retinopathy Study Severity Scale (ETDRS) and Diabetic Macular Edema (DME). More than mild DR (mtmDR) was defined as ETDRS level 35 or higher, and/or DME, in at least one eye. AI system operators underwent a standardized training protocol before study start. Median age was 59 years (range, 22-84 years); among participants, 47.5% of participants were male; 16.1% were Hispanic, 83.3% not Hispanic; 28.6% African American and 63.4% were not; 198 (23.8%) had mtmDR. The AI system exceeded all pre-specified superiority endpoints at sensitivity of 87.2% (95% CI, 81.8-91.2%) (>85%), specificity of 90.7% (95% CI, 88.3-92.7%) (>82.5%), and imageability rate of 96.1% (95% CI, 94.6-97.3%), demonstrating AI's ability to bring specialty-level diagnostics to primary care settings. Based on these results, FDA authorized the system for use by health care providers to detect more than mild DR and diabetic macular edema, making it, the first FDA authorized autonomous AI diagnostic system in any field of medicine, with the potential to help prevent vision loss in thousands of people with diabetes annually. ClinicalTrials.gov NCT02963441.

The authors' abstract, as published at the source. npj Digital Medicine, 2018 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiology, Nuclear Medicine and Imaging

Radiology, Nuclear Medicine and ImagingMedicine