3B yazdırılmış implant cerrahi rehberlerinin boyutsal stabilitesi ve oturma doÄŸruluÄŸu üzerindeki kalınlık, kemer tipi ve saklama süresinin etkisi

The effect of thickness, arch type, and storage duration on the dimensional stability and seating accuracy of 3d-printed implant surgical guides

Gan Jin, KyungHwan Kim, Sohee Lee, Yasunori Ayukawa ve diğerleri

Kısa özet

2 mm'den daha kalın ve kürleme sonrası en az 24 saat stabilize edilmesine izin verilen 3B yazdırılmış implant cerrahi rehberleri, geliÅŸtirilmiÅŸ boyutsal stabilite ve oturma doÄŸruluÄŸu göstermektedir.

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Ana noktalar

  • 3B yazdırılmış cerrahi rehberlerindeki deformasyonun çoÄŸu, üretimden sonraki 24 saat içinde meydana gelir.
  • 2 mm kalınlıktaki kısmi kemer rehberleri 7. günde önemli deformasyon göstermiÅŸtir (RMSE: 200.14 ± 37.52 µm).
  • 3 mm ve 4 mm kalınlıktaki kısmi kemer rehberleri ve tüm tam kemer rehberleri 14 gün boyunca boyutsal olarak stabil kalmıştır.
  • Tam kemer rehberleri, kısmi kemer rehberlerine göre daha tutarlı boyutsal stabilite göstermiÅŸtir.
  • Rehber kalınlığı, kemer aralığı ve saklama süresi, deformasyon ve oturma doÄŸruluÄŸunu önemli ölçüde etkilemiÅŸtir (p < 0.001).

Yapay zekâ ile başlık ve abstract'tan üretildi; tam metin okunmaz.

Özet (abstract)

This study investigated the effects of guide thickness, arch span, and storage duration on the dimensional stability and seating accuracy of 3D-printed implant surgical guides. Forty-eight surgical guides were fabricated using stereolithography (SLA) in partial-arch (PA) and full-arch (FA) surgical template designs across three thickness levels (2, 3, and 4 mm). All designs were fabricated for single-missing-tooth cases. The guides were stored for up to 14 days and evaluated at five time points (0, 1, 3, 7, and 14 days). Dimensional changes were quantified using root mean square error (RMSE) and visualized through colormap analysis, and seating accuracy was assessed by model-based mounting analysis. Most dimensional deformation occurred within the first 24 hours, with stabilization thereafter. Among PA guides, the 2-mm-thick group exhibited a pronounced increase in deformation at day 7 (RMSE: 200.14 ± 37.52 µm), whereas 3-mm and 4-mm PA guides remained dimensionally stable throughout the observation period (4-mm at day 14: 45.90 ± 3.73 µm). FA guides showed more consistent RMSE values across thicknesses and time points than PA guides (4-mm at day 14: 65.16 ± 0.47 µm) and maintained consistent seating accuracy throughout the study. Three-way ANOVA revealed significant main effects and interactions among thickness, arch span, and storage duration with respect to both deformation and seating accuracy (p < 0.001). Based on these findings, a minimum guide thickness of more than 2 mm is recommended and at least 24 h of post-curing stabilization should be observed before clinical use.

Yazarların özeti; kaynağından alınmıştır. Scientific Reports, 2026 · DOI ↗

ÇıkarımlarPremium
Makaleye SorÜcretsiz hesapla

Ücretsiz hesapla devam et

Makaleye Sor ile bu makaleye günde 3 soru ücretsiz; makaleyi kaydet, kaynakçasını al, ilgi alanına göre her gün yeni özetler. Çıkarımlar Premium.

Web'de ücretsiz devam et

Google ya da Apple hesabınla giriş; kart istemez. Bu makaleye geri dönersin.

Telefonda:

Alan: Ağız Cerrahisi

Oral SurgeryDentistry