Materials· 2026Q2
Effect of Additional Surface Conditioning Methods and Adhesive Systems on Microleakage at Composite Repair Interfaces: An in Vitro Study
- 0citations
- Q2SCImago
- 2026year
Short summary
No tested surface conditioning method (diamond bur, particle abrasion, or laser) or adhesive system (Clearfil SE Bond or Universal Bond Quick 2) significantly reduced microleakage at composite repair interfaces in extracted teeth.
AI-generated from the title and abstract; the full text is not read.
Key points
- Three surface conditioning methods (diamond bur, particle abrasion, laser) were tested for composite repair interfaces.
- Two adhesive systems (Clearfil SE Bond, Clearfil Universal Bond Quick 2) were evaluated.
- No significant difference in linear microleakage was found between conditioning methods, adhesive systems, or their interaction.
- Ordinal analysis also showed no statistically significant effect of the tested methods or adhesives on microleakage.
AI-generated from the title and abstract; the full text is not read.
Abstract
Repair of aged resin composites requires additional surface conditioning and an adhesive protocol capable of limiting interfacial leakage. This in vitro study evaluated three additional conditioning methods and two adhesive systems at aged composite–new composite repair interfaces. Ninety extracted posterior teeth were restored, thermocycled, and partially prepared with a diamond bur to create standardized repair surfaces. The surfaces then received additional diamond-bur roughening, 50-µm Al2O3 airborne-particle abrasion, or Er:YAG laser irradiation and were treated with Clearfil SE Bond or Clearfil Universal Bond Quick 2 (n = 15 per combination). After repair and additional thermocycling, maximum linear dye penetration was measured as the primary outcome; a derived ordinal grade was analyzed as a supportive, exploratory secondary outcome. A two-factor permutation analysis detected no significant effect of conditioning method (p = 0.142), adhesive system (p = 0.606), or their interaction (p = 0.341) on linear microleakage. In the ordinal proportional-odds analysis, the method effect was not statistically significant (p = 0.053); neither the adhesive effect (p = 0.763) nor the interaction (p = 0.754) was significant. Under the tested conditions, statistically significant differences in microleakage were not detected among the evaluated combinations.
The authors' abstract, as published at the source. Materials, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Orthodontics
OrthodonticsDentistry