Nature Communications· 2012Q1
Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light
- 360citations
- Q1SCImago
- 2012year
Short summary
Researchers demonstrate deep-tissue fluorescence imaging at 2.5 mm depth with 36 μm lateral resolution by digitally time-reversing ultrasound-tagged light, achieving an optical gain of ~5x10^5.
AI-generated from the title and abstract; the full text is not read.
Key points
- Achieved deep-tissue fluorescence imaging at 2.5 mm depth in biological tissues.
- Employed digitally time-reversed ultrasound-encoded light for focusing.
- Demonstrated high optical gain of ~5x10^5.
- Obtained a lateral resolution of 36 μm x 52 μm and axial resolution of 657 μm.
- Successfully imaged complex fluorescent objects and tumor microtissues.
AI-generated from the title and abstract; the full text is not read.
Abstract
Fluorescence imaging is one of the most important research tools in biomedical sciences. However, scattering of light severely impedes imaging of thick biological samples beyond the ballistic regime. Here we directly show focusing and high-resolution fluorescence imaging deep inside biological tissues by digitally time-reversing ultrasound-tagged light with high optical gain (~5×105). We confirm the presence of a time-reversed optical focus along with a diffuse background—a corollary of partial phase conjugation—and develop an approach for dynamic background cancellation. To illustrate the potential of our method, we image complex fluorescent objects and tumour microtissues at an unprecedented depth of 2.5 mm in biological tissues at a lateral resolution of 36 μm×52 μm and an axial resolution of 657 μm. Our results set the stage for a range of deep-tissue imaging applications in biomedical research and medical diagnostics. Fluorescence imaging is important for biomedical research and applications, but the turbidity of biological material prohibits deep tissue study. By combining ultrasound-encoding with digital time-reversal, Wanget al.perform focussed fluorescence imaging at a tissue depth of 2.5mm.
The authors' abstract, as published at the source. Nature Communications, 2012 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Acoustics and Ultrasonics
Acoustics and UltrasonicsPhysics and Astronomy