Biomedical Optics Express· 2014Q1

Multiplexed coded illumination for Fourier Ptychography with an LED array microscope

Lei Tian, Xiao Li, Kannan Ramchandran, Laura Waller

Short summary

A new multiplexed illumination strategy for Fourier Ptychography significantly reduces image acquisition time and data requirements by turning on multiple LEDs simultaneously, achieving similar image quality to sequential methods.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Multiplexed illumination activates multiple LEDs simultaneously for Fourier Ptychography.
  • Reduces image acquisition time by an order of magnitude compared to sequential illumination.
  • Maintains image quality comparable to sequential scanning methods.
  • Decreases data capture requirements by approximately tenfold.

AI-generated from the title and abstract; the full text is not read.

Abstract

Fourier Ptychography is a new computational microscopy technique that achieves gigapixel images with both wide field of view and high resolution in both phase and amplitude. The hardware setup involves a simple replacement of the microscope's illumination unit with a programmable LED array, allowing one to flexibly pattern illumination angles without any moving parts. In previous work, a series of low-resolution images was taken by sequentially turning on each single LED in the array, and the data were then combined to recover a bandwidth much higher than the one allowed by the original imaging system. Here, we demonstrate a multiplexed illumination strategy in which multiple randomly selected LEDs are turned on for each image. Since each LED corresponds to a different area of Fourier space, the total number of images can be significantly reduced, without sacrificing image quality. We demonstrate this method experimentally in a modified commercial microscope. Compared to sequential scanning, our multiplexed strategy achieves similar results with approximately an order of magnitude reduction in both acquisition time and data capture requirements.

The authors' abstract, as published at the source. Biomedical Optics Express, 2014 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiation

RadiationPhysics and Astronomy