Daily full online replanning on the Elekta Unity MR-linac is the most robust adaptive radiotherapy method, meeting all clinical dose constraints for tested sites within clinically acceptable times (17-485s).

AI-generated from the title and abstract; the full text is not read.

Key points

  • Daily full online replanning is the most robust adaptive radiotherapy method for the Elekta Unity MR-linac.
  • Adaptation times for tested methods ranged from 17 to 485 seconds.
  • More advanced adaptation methods generally resulted in more plans meeting clinical dose criteria.
  • Full online replanning achieved plans meeting all clinical dose constraints for all simulated cases.

AI-generated from the title and abstract; the full text is not read.

Abstract

BACKGROUND AND PURPOSE: The promise of the MR-linac is that one can visualize all anatomical changes during the course of radiotherapy and hence adapt the treatment plan in order to always have the optimal treatment. Yet, there is a trade-off to be made between the time spent for adapting the treatment plan against the dosimetric gain. In this work, the various daily plan adaptation methods will be presented and applied on a variety of tumour sites. The aim is to provide an insight in the behavior of the state-of-the-art 1.5 T MRI guided on-line adaptive radiotherapy methods. MATERIALS AND METHODS: To explore the different available plan adaptation workflows and methods, we have simulated online plan adaptation for five cases with varying levels of inter-fraction motion, regions of interest and target sizes: prostate, rectum, esophagus and lymph node oligometastases (single and multiple target). The plans were evaluated based on the clinical dose constraints and the optimization time was measured. RESULTS: The time needed for plan adaptation ranged between 17 and 485 s. More advanced plan adaptation methods generally resulted in more plans that met the clinical dose criteria. Violations were often caused by insufficient PTV coverage or, for the multiple lymph node case, a too high dose to OAR in the vicinity of the PTV. With full online replanning it was possible to create plans that met all clinical dose constraints for all cases. CONCLUSION: Daily full online replanning is the most robust adaptive planning method for Unity. It is feasible for specific sites in clinically acceptable times. Faster methods are available, but before applying these, the specific use cases should be explored dosimetrically.

The authors' abstract, as published at the source. Clinical and Translational Radiation Oncology, 2019 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Radiation

RadiationPhysics and Astronomy