Brazilian Journal of Physical Therapy· 2026Q1
Chelsea critical care physical assessment tool (CPAx) for adult patients hospitalized in the ward: measurement properties
- 0citations
- Q1SCImago
- 2026year
Short summary
The Brazilian version of the Chelsea Critical Care Physical Assessment Tool (CPAx-Br) shows good reliability (ICC=0.99) and validity for assessing physical function in adult general ward patients, extending its use beyond critical care.
AI-generated from the title and abstract; the full text is not read.
Key points
- The CPAx-Br showed high reliability (ICC=0.99) and low measurement error (SEM=0.985) in adult general ward patients.
- Strong evidence for construct validity was found, with a high positive correlation between CPAx-Br and DEMMI (r=0.895).
- The tool demonstrated acceptable external responsiveness (r=0.70) and discriminative ability (AUC=0.70).
- No floor effect was observed, but a ceiling effect of 16% was noted.
AI-generated from the title and abstract; the full text is not read.
Abstract
Objective To evaluate the measurement properties of the Brazilian version of the Chelsea Critical Care Physical Assessment Tool (CPAx-Br) and evaluate the evidence of validity in adult general ward patients, extending its application beyond the critical care setting for which it was originally developed. Methods This longitudinal study included 100 adults (57.5 ± 16.7 years; 54% female) consecutively admitted to hospital wards. The CPAx-Br was applied at three time points: within 48 h of admission, alongside the De Morton Mobility Index (DEMMI) and the Global Rating Scale of Change (GRC); 24 h later to assess reliability; and at hospital discharge, again with the DEMMI and GRC. As part of construct validity, hypothesis testing was performed using Spearman's correlation with the DEMMI. Reliability was tested using the Intraclass Correlation Coefficient (ICC 2,1 ) and Standard Error of Measurement (SEM). Responsiveness was evaluated using ROC curve analysis, effect size (ES), and correlation with external measures. Floor and ceiling effects were also examined. Results The CPAx-Br demonstrated adequate reliability (ICC 2,1 = 0.99; 95%CI:0.99–1.00) and measurement error (SEM=0.985). Evidence supporting construct validity was obtained through hypothesis testing, demonstrating a positive correlation with the DEMMI (r = 0.895; p < 0.001). Internal responsiveness was low (ES=0.35), while external met the predefined criterion (r = 0.70; p < 0.001). The CPAx-Br showed acceptable discriminative ability (AUC=0.70; 95% CI 0.54 to 0.85), with no floor effect (0%), whereas the ceiling effect was 16%. Conclusion The CPAx-Br demonstrated validity based on hypothesis testing, as well as good reliability and acceptable responsiveness for assessing physical function among adult ward patients.
The authors' abstract, as published at the source. Brazilian Journal of Physical Therapy, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Critical Care and Intensive Care Medicine
Critical Care and Intensive Care MedicineMedicine