Intensive and Critical Care Nursing· 2026Q1· Review

Measurement properties of instruments for post-extubation dysphagia in critically ill patients: A systematic review

Lilly Koppelkamm, Martin Eicher, Peter Nydahl, Jan Matthias Kruse et al.

Short summary

A systematic review identified 16 instruments to assess post-extubation dysphagia (PED) in critically ill patients, with the Post-Extubation Dysphagia Screening Tool showing sufficient measurement properties across validity and reliability, though overall evidence quality was low.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Sixteen different instruments were identified for assessing post-extubation dysphagia (PED) in critically ill adults.
  • Nine instruments reported on measurement properties, with most showing good criterion validity, content validity, and reliability.
  • The Post-Extubation Dysphagia Screening Tool was the only instrument evaluated across all three properties (content validity, criterion validity, reliability) and demonstrated sufficient measurement properties.
  • The overall quality of evidence for the measurement properties of these instruments was mostly low to very low.

AI-generated from the title and abstract; the full text is not read.

Abstract

OBJECTIVES: Post-extubation dysphagia (PED) is a common but often under-recognised complication in critically ill patients following invasive mechanical ventilation. Systematic assessment of PED in routine ICU practice is not common. This systematic review aimed to identify clinical instruments used to assess PED in critically ill adult patients and to evaluate their measurement properties. METHODS: This review was conducted in accordance with the COSMIN methodology for systematic reviews of measurement instruments. A comprehensive evidence search was performed in multiple databases and other sources. Studies were included if they developed or applied standardised assessment instruments for the identification of PED in critically ill adults (≥18 years). RESULTS: Of 2769 abstracts reviewed, 22 studies met criteria for inclusion. Sixteen different instruments for the assessment of PED were identified. These were categorised into water swallow tests, multi-consistency tests, and assessments without a swallowing evaluation. For nine instruments, measurement properties were reported, focusing on content validity, criterion validity and reliability, and demonstrated mostly good measurement properties. The Post-Extubation Dysphagia Screening Tool was the only evaluated across all three properties and showed sufficient measurement properties. The overall quality of evidence was mostly low to very low. CONCLUSIONS: There are various clinical assessment instruments for PED in critically ill adults. Most instruments showed good criterion validity, indicating their potential for clinical use. However, other measurement properties are largely unknown, and the quality of evidence is generally low. Thus, it is currently unclear which tool is best suited for assessing PED. Further research investigating validity and reliability is needed to identify instruments suitable for routine ICU use. IMPLICATIONS FOR CLINICAL PRACTICE: Systematic detection of PED is important. Assessment instruments with good diagnostic performance should be used to improve ICU care.

The authors' abstract, as published at the source. Intensive and Critical Care Nursing, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Speech and Hearing

Speech and HearingHealth Professions