PofoliaShared via Pofolia

Harm Reduction Journal· 2026Q1

Drug trash to treasure: quantitative mass spectrometric analysis of residual drugs from used lateral flow immunoassay test strips and syringe plungers

Hirudini Fernando, Heather D. Whitehead, Nicholas J Black, Eric D West et al.

Short summary

A new LC-MS/MS method quantifies drug residues (down to 0.5 ng/mL) from used lateral flow test strips and syringe plungers, achieving 12-87% extraction efficiency for 21 drugs after 4 weeks of room-temperature storage.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed an LC-MS/MS method to quantify drug residues on used test strips and syringe plungers.
  • Method detects drugs down to 0.5 ng/mL, including high-potency substances like carfentanil.
  • Methanol was the optimal extraction solvent; test strip type did not affect recovery.
  • Recovered 12-87% of 21 targeted drugs after four weeks of room-temperature storage.

AI-generated from the title and abstract; the full text is not read.

Abstract

Abstract Introduction A major challenge to monitoring street drugs is the difficulty of obtaining samples of illegal substances for laboratory analysis. However, liquid chromatography-mass spectrometry (LC-MS/MS) can detect drug residues on legal materials, such as drug checking test strips, that contact drug substances. This study evaluates the feasibility of incorporating used test strips and used syringe plungers into routine laboratory drug checking. Methods Three factors that affect the recovery of 21 drugs from the test strips were assessed: the extraction solvent, test strip type, and analyte stability during storage. Seized drug samples were prepared quantitatively and applied to test strips, syringes, and syringe plungers to compare qualitative and quantitative recoveries. The applicability of the extraction methods was further assessed using authentic samples from Ohio and Massachusetts. Results The developed LC-MS/MS method successfully quantified most of the analytes to a concentration of 0.5 ng/mL, enabling the detection of clinically relevant amounts of drugs, including high-potency drugs like carfentanil and medetomidine. Methanol worked best to extract the drugs, the type of the strips did not impact recovery, and all 21 targeted drugs could be recovered with 12–87% extraction efficiency after four weeks of storage of the strips at room temperature. Conclusion Extracting drug residues from used test strips and syringe plungers was feasible and robust to solvent, brand, and storage challenges. Use of these samples reduces the burden of collecting unregulated solid drug samples, enhances staff safety, and provides a seamless integration of laboratory-based techniques into monitoring protocols.

The authors' abstract, as published at the source. Harm Reduction Journal, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

ToxicologyPharmacology, Toxicology and Pharmaceutics