Skin-on-a-Chip for Cosmetic Safety Assessment: From Reconstructed Skin Models to Regulatory Translation
- 0citations
- Q1SCImago
- 2026year
Short summary
Skin-on-a-chip (SoC) models are proposed as a higher-tier complement to established reconstructed human epidermis (RhE) and skin (RhS) models for cosmetic safety assessment, but require significant validation for regulatory acceptance.
AI-generated from the title and abstract; the full text is not read.
Key points
- Skin-on-a-chip (SoC) models can address specific cosmetic safety questions not fully resolved by reconstructed human epidermis (RhE) or skin (RhS) models.
- SoC testing is recommended only when established methods leave decision-relevant uncertainty.
- Translating SoC models for regulatory acceptance requires four stages: analytical validation, biological validation, context-of-use qualification, and regulatory acceptance.
- Decision-ready readouts from SoC models necessitate traceable calibration, explicit units, prespecified normalization, drift control, variability estimates, comparator agreement, and quantitative acceptance criteria.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Cosmetic safety assessment increasingly relies on human-relevant nonanimal methods that support mechanistic interpretation and align with a defined decision context. Reconstructed human epidermis (RhE) supports accepted irritation and corrosion procedures. Reconstructed human skin (RhS) and full-thickness equivalents provide tissue-level comparators for dermal architecture, penetration, and recovery. These models are distinct comparator classes. Rather than cataloging skin-on-a-chip (SoC) architectures, this review assigns an appropriate comparator to each cosmetic-safety question. It then defines the residual uncertainty that may justify SoC testing. It also specifies required readouts and evidence thresholds for a prespecified decision. Vascular and immune modules, controlled topical dosing, and multiorgan coupling are considered only when they address unresolved time course, exposure route, tissue context, or mechanism. Decision-ready readouts require traceable calibration, explicit units, prespecified normalization, drift control, variability estimates, comparator agreement, and quantitative acceptance criteria. No reviewed skin SoC has broad regulatory acceptance for routine cosmetic-safety decisions. Translation therefore requires four distinct stages: analytical validation, biological validation, context-of-use qualification, and regulatory acceptance. Current evidence supports SoC mainly as a higher-tier complement when established methods leave a decision-relevant uncertainty.
The authors' abstract, as published at the source. ACS Omega, 2026 · DOI ↗