American Journal of Critical Care· 2026Q1
Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury
- 0citations
- Q1SCImago
- 2026year
Short summary
Ultrasonographic pupil assessment through a closed eyelid accurately measures pupillary constriction (median difference 0.44%) and resting/minimum diameters (r² 0.6-0.873) compared to direct pupillometry in severe TBI patients.
AI-generated from the title and abstract; the full text is not read.
Key points
- Ultrasonography through the closed eyelid is a feasible and accurate method for pupillary assessment in severe TBI.
- The technique showed excellent agreement with direct pupillometry for pupillary constriction percentage (median difference 0.44%).
- Strong correlations were observed between ultrasonography and direct pupillometry for resting and minimum pupil diameters (0.6 ≤ r² ≤ 0.873).
- This method overcomes limitations of direct visualization caused by periorbital edema, trauma, or dressings.
AI-generated from the title and abstract; the full text is not read.
Abstract
Background In patients with severe traumatic brain injury, accurate pupillary assessment is critical for neurological monitoring but is often hindered by periorbital edema, trauma, or dressings that preclude direct visualization. Objective To validate the feasibility and accuracy of ultrasonographic pupil assessment performed through the closed eyelid as an alternative to direct pupillometry in patients with traumatic brain injury. Methods This prospective study enrolled 45 intensive care unit patients (36 male; mean [SD] age, 67.1 [12.9] years). Both direct pupillometry and ultrasonographic pupil assessment were sequentially completed within a 3-minute interval under standardized low-light conditions for both eyes. Direct pupillometry involved video recording of the exposed pupil with a calibrated reference scale. Ultrasonographic pupil assessment was performed by using a high-frequency linear probe placed on the closed eyelid. The primary outcome was the agreement between methods for calculating the percentage of pupillary constriction. Secondary outcomes included agreement on resting and minimum pupil diameters. Results Ultrasonographic pupil assessment showed excellent agreement with direct pupillometry for percent pupillary constriction (median [IQR] difference, 0.44% [−2.78% to 2.83%]; Wilcoxon P ≥ .48). Bland-Altman analysis showed narrow limits of agreement. Strong correlations were also noted for resting and minimum pupil diameters (0.6 ≤ r2 ≤ 0.873). Conclusion Ultrasonographic pupil assessment is a reliable and accurate method for objective pupillary evaluation when direct visualization is obstructed. By enabling quantitative measurement of the pupillary light reflex through the closed eyelid, ultrasonographic pupil assessment addresses an important monitoring gap in the management of patients with severe traumatic brain injury and periorbital swelling.
The authors' abstract, as published at the source. American Journal of Critical Care, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Critical Care and Intensive Care Medicine
Critical Care and Intensive Care MedicineMedicine