Case Studies in Thermal Engineering· 2026Q1
Composite energy geo-structures for building decarbonization
- 0citations
- Q1SCImago
- 2026year
Short summary
A composite energy geo-structure system integrating energy tunnels, diaphragm walls, piles, and boreholes achieved 1.90 to 24.87 times greater total heat exchange capacity than standalone systems, reducing annual operational emissions by 49.80% compared to coal heating and electric air-conditioning.
AI-generated from the title and abstract; the full text is not read.
Key points
- A composite energy geo-structure system integrates energy tunnels, diaphragm walls, piles, and boreholes.
- The composite system achieved 1.90x (ET), 2.70x (EDW), 11.24x (EP groups), and 24.87x (BHE arrays) greater total heat exchange capacity than standalone components.
- The system demonstrated a repeatable seasonal thermal response after the first year.
- Compared to coal-fired heating and electric air-conditioning, the composite system reduced annual operational emissions by 49.80% (962.03 t CO2-eq).
AI-generated from the title and abstract; the full text is not read.
Abstract
Energy geo-structures (EGs) integrate heat-exchange loops into geotechnical structures to provide heating and cooling using shallow geothermal energy. However, the contribution of standalone EGs to building thermal demand may decrease in large-scale applications and can be accompanied by seasonal ground thermal imbalance. To overcome the limitations of standalone EGs, a composite EG system integrating energy tunnels (ET), energy diaphragm walls (EDW), energy piles (EP), and boreholes (BHE) is proposed. A three-dimensional numerical model of a composite energy geo-structure system was established and evaluated against experimental or published benchmark data for the component subsystems. The model was used to investigate the short- and long-term thermal performance of the composite system. The results show that, despite localized reductions in the heat flux in length of EP and BHE, the composite EGs achieved a higher total heat exchange capacity—1.90, 2.70, 11.24, and 24.87 times greater than those of standalone ET, EDW, EP groups, and BHE arrays, respectively. Over the ten-year simulation, ET and EDW showed limited interannual variation, while the EP-BHE subsystem approached a repeatable seasonal response after the first complete annual cycle. Additionally, under the prescribed building-load conditions, circulating flow rate and soil thermal conductivity mainly altered the local ground-temperature field, whereas annual heat exchange was primarily determined by the imposed building demand and the COP-dependent ground-side load. Compared with coal-fired heating and electric air-conditioning under the same building load, the composite system reduced annual operational emissions by 49.80% (962.03 t CO 2 -eq), demonstrating its potential for efficient and low-carbon building thermal supply.
The authors' abstract, as published at the source. Case Studies in Thermal Engineering, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Renewable Energy, Sustainability and the Environment
Renewable Energy, Sustainability and the EnvironmentEnergy