PofoliaShared via Pofolia

Computational Particle Mechanics· 2026Q1

Modeling particle transport in biomedical flows using implicit geometry representations

J. Scott Malloy, Sreeparna Majee, Akshita Sahni, Ricardo Roopnarinesingh et al.

Short summary

A new particle dynamics model uses signed distance fields to represent anatomical features, enabling efficient and accurate simulation of particle transport in biomedical flows, such as embolic particles in human vasculature.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Developed an efficient particle dynamics model using signed distance fields for implicit geometry representation.
  • The model transforms Lagrangian contact detection into an Eulerian operation for computational efficiency.
  • Validated performance and accuracy with simplified geometries and a human vascular segment simulation.
  • Achieved significant speed-up in bulk particle dynamics computations without compromising accuracy or geometric fidelity.

AI-generated from the title and abstract; the full text is not read.

Abstract

Computational analysis of physiological and biomedical systems necessitate efficient geometry representations for high fidelity model predictions, including patient or device specificity. Particle-based Lagrangian computational approaches comprise a valuable approach to gain insights from quantitative velocity and pressure data from computational models. Examples include particle dynamics and transport in human vasculature for diseases such as stroke, thrombosis, and embolisms; and modern targeted drug delivery systems in the vascular network and respiratory airways. However, current particle simulation approaches can bear significant computational expense that scales with both number of particles and background fluid mesh resolution. A significant determinant of this computational expense is the contact resolution between particles and anatomically realistic vessel wall. Here, we develop an efficient particle dynamics model that leverages an implicit representation of real anatomical features using a signed distance field to efficiently resolve particle-wall contact. We outline the underlying algorithmic details, followed by a systematic illustration of performance and accuracy using simplified and analytically defined geometries and flow fields. Subsequently, we present a representative simulation of embolic particles along a human vascular segment where we compare our distance field-based approach against classical wall-contact checks based on assessing particle boundary intersection with triangulated surface mesh. Our approach transforms the underlying Lagrangian contact detection operation into an equivalent Eulerian operation, significantly speeding up bulk particle dynamics computations without significantly impacting accuracy or geometric fidelity.

The authors' abstract, as published at the source. Computational Particle Mechanics, 2026 · DOI ↗

TakeawaysPremium
Ask the paperFree account

Continue with a free account

Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Computer Graphics and Computer-Aided Design

Computer Graphics and Computer-Aided DesignComputer Science