Journal of Nuclear Science and Technology· 2026Q2
Evaluation of false alarm characteristics and majority-voting logic integration of spectral-based discrimination methods for continuous air monitors
- 0citations
- Q2SCImago
- 2026year
Short summary
Combining spectral discrimination methods (ROI-1/ROI-2 ratio, correlation-based, and α/β ratio) using majority-voting logic significantly reduces false alarms in continuous air monitors (CAMs) compared to single methods.
AI-generated from the title and abstract; the full text is not read.
Key points
- ROI-1/ROI-2 ratio method is prone to false alarms at low 218Po concentrations and low total acquisition counts.
- Correlation-based and α/β ratio methods are affected by fluctuations in natural radionuclide concentration ratios.
- No single discrimination method achieves ideal performance.
- Majority-voting logic integrating multiple methods effectively reduces false alarm events.
AI-generated from the title and abstract; the full text is not read.
Abstract
Continuous air monitors (CAMs) are essential devices for the rapid detection of accidental releases of artificial radionuclides at nuclear facilities. However, false alarms are frequently observed even in the absence of transuranium elements (TRUs) posing a challenge for radiation safety management. In this study, three discrimination methods – the ROI-1/ROI-2 ratio method (where ROI stands for region of interest), the correlation-based method, and the α/β ratio method – were evaluated simultaneously under identical conditions using a CAM equipped with a silicon semiconductor detector. The performance tests revealed distinct characteristics and vulnerabilities for each algorithm. The ROI-1/ROI-2 ratio method was prone to false alarms during periods of low 218Po concentration and low total acquisition counts. On the other hand, the correlation-based and α/β ratio methods were affected by fluctuations in the concentration ratios of naturally occurring background radionuclides. Although ideal discrimination cannot be achieved using any single method alone, the results suggest that combining multiple methods based on majority-voting logic can effectively reduce false alarm events and improve system reliability. These findings will contribute to the development of more reliable atmospheric radiation monitoring technologies.
The authors' abstract, as published at the source. Journal of Nuclear Science and Technology, 2026 · DOI ↗
Continue with a free account
Ask the paper: 3 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Radiological and Ultrasound Technology
Radiological and Ultrasound TechnologyHealth Professions