PofoliaDaily literature tracker

Biomedical Signal Processing and Control· 2026Q1

Artifact detection and localization in single-channel mobile EEG for sleep research using deep learning and attention mechanisms

Khrystyna Semkiv, Jia Zhang, Maria Laura Ferster, Walter Karlen

Short summary

A CNN-CBAM model achieved 0.88 AUC, 0.81 sensitivity, and 0.86 specificity for detecting sleep EEG artifacts, outperforming 6 other methods on single-channel mobile recordings.

AI-generated from the title and abstract; the full text is not read.

Key points

  • A CNN-CBAM model was developed for artifact detection and localization in single-channel mobile sleep EEG.
  • The model achieved an AUC of 0.88, sensitivity of 0.81, and specificity of 0.86, outperforming six other methods.
  • Attention maps from the CNN-CBAM model localized artifacts within detected epochs with 0.61 sensitivity and 0.63 specificity.
  • The study used 72 annotated recordings for training/tuning and 26 for testing from healthy participants aged ~68 years.

AI-generated from the title and abstract; the full text is not read.

Abstract

Artifacts in the electroencephalogram (EEG) degrade signal quality and impact the analysis of brain activity. Current methods for detecting artifacts in sleep EEG range from threshold-based algorithms to machine learning approaches, yet applications remain limited for single-channel mobile EEG. We propose a convolutional neural network (CNN) model incorporating a convolutional block attention module (CNN-CBAM) to detect and localize artifacts in sleep EEG using attention maps. We benchmarked this model against 6 other machine learning and signal processing approaches. We trained/tuned all models on 72 manually annotated EEG recordings obtained during home-based monitoring from 18 healthy participants with a mean (SD) age of 68.05 y ( ± 5.02). We tested them on 26 separate recordings from 6 healthy participants with a mean (SD) age of 68.33 y ( ± 4.08), which contained artifacts in 4% of epochs. CNN-CBAM achieved the highest area under the receiver operating characteristic curve (0.88), sensitivity (0.81), and specificity (0.86) among the tested approaches. Under the ideal choice of an attention threshold of 0.66, the attention maps from CNN-CBAM localized artifacts within detected artifact epochs with a sensitivity of 0.61 and specificity of 0.63. This work demonstrates the feasibility of automating artifact detection and localization in wearable sleep EEG.

The authors' abstract, as published at the source. Biomedical Signal Processing and Control, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Cognitive Neuroscience

Cognitive NeuroscienceNeuroscience