PofoliaDaily literature tracker

Ultramicroscopy· 2026Q1

Scan-coil delay causes anisotropic signal loss in fast 4D-STEM

Vishal Kumar, Andreas Jehle, Tizian Lorenzen, Julika Radecke et al.

Short summary

A new sub-frame alignment procedure corrects anisotropic signal smearing in fast 4D-STEM data caused by scan-coil delays, recovering signal lost at large scan step sizes crucial for low-dose biological imaging.

AI-generated from the title and abstract; the full text is not read.

Key points

  • Scan-coil delays in fast 4D-STEM cause anisotropic signal smearing with settling times of tens of microseconds.
  • A novel phase-correlation-based sub-frame alignment procedure is presented to measure and correct this smearing.
  • The correction method restores signal across a wide range of spatial frequencies.
  • Largest signal gains are observed at large scan step sizes, essential for low-dose biological imaging.
  • The method operates on existing data, requiring no microscope modifications.

AI-generated from the title and abstract; the full text is not read.

Abstract

Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.

The authors' abstract, as published at the source. Ultramicroscopy, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Structural BiologyBiochemistry, Genetics and Molecular Biology