PofoliaDaily literature tracker

Scientific Reports· 2026Q1

A physics-informed graph attention enhanced CNN-GRU coupling model for fire spread path prediction in chemical industrial parks

Qiaodi Lei

Short summary

A new physics-informed graph attention enhanced CNN-GRU model (PI-GAT-CNN-GRU) accurately predicts fire spread paths in industrial parks, achieving an F1 score of 0.6187, outperforming the strongest baseline by 11% and predicting with 89.4% coverage of empirical ignition frequencies.

AI-generated from the title and abstract; the full text is not read.

Key points

  • PI-GAT-CNN-GRU model integrates physics (radiation, flame tilt, shielding) into graph attention for fire spread prediction.
  • Achieved F1 score of 0.6187 on 1152 FDS scenarios, outperforming baseline FSTGAT (F1=0.5561).
  • Physics loss reduced physical relation violations from 25.5% to 12.2%; scheduled sampling lowered error amplification from 3.42 to 1.84.
  • Demonstrates strong generalization (>=80.6% F1 retention) on new parks without retraining and matches real-world fire order (Kendall's tau_b = 0.60).
  • Provides uncertainty quantification covering 89.4% of empirical ignition frequencies and enables rapid 3600s prediction in 0.43s.

AI-generated from the title and abstract; the full text is not read.

Abstract

Fire escalation in tank farms is a major process safety risk, but CFD simulation is too slow for emergency use and purely data driven models ignore the irregular layout and the physics of radiative escalation. This work proposes PI-GAT-CNN-GRU, a physics-informed graph attention enhanced CNN-GRU model that forecasts fire spread paths under a strictly causal protocol and decodes node probabilities into ordered cascade paths, with a stochastic decoding of concurrent escalation. Radiation edge weights with an explicit radiative fraction, flame tilt and shielding are injected into graph attention, a causal temporal convolution and a GRU are rolled out autoregressively with quantified error amplification, and a composite loss encodes effective distance attenuation, view factor consistency, wind weighting and cumulative thermal dose, complemented by energy conserving constraints. On 1152 FDS scenarios of a 32 tank park, PI-GAT-CNN-GRU reaches F1 = 0.6187, PR-AUC = 0.6521, MCC = 0.5966 and PHR@Top-3 = 0.6784, against 0.5561, 0.5813, 0.5296 and 0.5789 for the strongest baseline FSTGAT, and the physics loss reduces the violation rate of four physical relations from 25.5% to 12.2%, while scheduled sampling lowers the error amplification ratio from 3.42 to 1.84. F1 retention is at least 80.6% on three further parks without retraining, 87.2% when the 32 tank park is held out and 91.7% on held out procedurally generated layouts, and Kendall’s $$\tau_{b}$$ with the documented order of the 2019 Deer Park tank farm fire is 0.60. The 95% intervals of MC dropout and a deep ensemble cover 89.4% of the empirical ignition frequencies under FDS input perturbations, the forecast error is of the same order as the scatter of the FDS labels, and a 3600 s rollout takes 0.43 s.

The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗

TakeawaysPremium Ask the paperFree account

Continue with a free account

Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.

Continue free on the web

Sign in with Google or Apple; no card needed. You come back to this paper.

On your phone:

Field: Safety, Risk, Reliability and Quality

Safety, Risk, Reliability and QualityEngineering