Scientific Reports· 2026Q1
Green and simple rrs spectroscopic strategy based on xanthene-based dye; Acid Red 51 for eletriptan quantification in pharmaceuticals and biological samples
- 0citations
- Q1SCImago
- 2026year
Short summary
A new, one-pot resonance Rayleigh Scattering (RRS) method using Acid Red 51 dye can quantify eletriptan in pharmaceuticals and biological samples with high sensitivity, with a linear range of 50-1500 ng/mL.
AI-generated from the title and abstract; the full text is not read.
Key points
- A novel, one-pot resonance Rayleigh Scattering (RRS) method was established for eletriptan quantification.
- The method uses the fluorescent dye Acid Red 51 to form an ion-pair complex with eletriptan, amplifying the RRS signal.
- A linear relationship was observed between RRS intensity and eletriptan concentration from 50 to 1500 ng/mL.
- The method achieved low detection (15.7 ng/mL) and quantification (47.8 ng/mL) limits.
- The technique is validated, accurate, reproducible, and environmentally friendly, suitable for pharmaceutical and biological samples.
AI-generated from the title and abstract; the full text is not read.
Abstract
Abstract Eletriptan tablets are a targeted pharmaceutical agent that acts as an agonist for the 5-hydroxytryptamine1 receptor subclassification, mostly employed to alleviate acute migraine episodes. As a member of the triptan class, Eletriptan functions by constricting cerebral blood vessels and decreasing the release of chemicals that cause light and sound sensitivity, nausea, and headache discomfort. Its efficacy in alleviating migraine symptoms makes it a valuable option for individuals seeking rapid and effective relief. A sustainable, rapid, one-pot resonance Resonance Rayleigh Scattering spectrometric technique was created for estimating out Eletriptan in pharmaceutical tablets and biological matrices. Upon mixing Eletriptan with the fluorescent ligand Acid Red 51 in an acidic buffer, a marked increase in resonance Resonance Rayleigh Scattering intensity was immediately observed. This phenomenon was ascribed to the selective formation of an ion-pair complex between the cationic Eletriptan drug and the anionic dye, which amplified the Resonance Rayleigh Scattering signal through enhanced scattering interactions. The RRS intensity showed a straight-line connection with Eletriptan concentration between 50 and 1500 ng/mL, allowing for accurate measurement. Key experimental parameters, including pH, ligand concentration, and buffer volume, were systematically optimized to maximize the sensitivity of the Eletriptan –Acid Red 51 system. The method adhered to International Council for Harmonisation validation criteria, achieving detection and quantification limits of 15.7 ng/mL and 47.8 ng/mL, respectively. Effective implementation to pharmaceutical and biological samples confirmed the method’s accuracy and reproducibility, with recovery rates aligning with acceptable analytical standards. Notably, the approach minimizes solvent consumption and hazardous waste generation, aligning with green analytical principles. By integrating simplicity, environmental sustainability, and high sensitivity, this Resonance Rayleigh Scattering-based technique emerges as a robust alternative for routine analysis of Eletriptan in quality control and biomedical research.
The authors' abstract, as published at the source. Scientific Reports, 2026 · DOI ↗
Continue with a free account
Ask the paper: 5 free questions a day about this paper; save it, get its citation, new summaries every day for your field. Takeaways are Premium.
Continue free on the webSign in with Google or Apple; no card needed. You come back to this paper.
On your phone:
Field: Analytical Chemistry
Analytical ChemistryChemistry